1.

 

Enter Setup 

Setup 

Setup 

Setup mode by pressing and holding the HOLD

HOLD

HOLD

HOLD/SETUP

/SETUP

/SETUP

/SETUP key for 4 seconds.     

2.

 

After entering SSSSetup

etup

etup

etup Mode, the main menu item “CONFIG

CONFIG

CONFIG

CONFIG”””” will be displayed. Do NOT

NOT

NOT

NOT enter CONFIG 

CONFIG 

CONFIG 

CONFIG Setup Mode. Use the arrow keys to 

move to MISC

MISC

MISC

MISC Mode, then press TARE/PRESET

TARE/PRESET

TARE/PRESET

TARE/PRESET to enter miscellaneous setting mode. If you enter the wrong mode, press the    

HOLD

HOLD

HOLD

HOLD/SETUP

/SETUP

/SETUP

/SETUP    key to return to the main menu, or press    ZERO/ON/OFF

ZERO/ON/OFF

ZERO/ON/OFF

ZERO/ON/OFF at any time to exit setup. 

3.

 

After entering MISC

MISC

MISC

MISC Mode, the submenu item    ““““CCCCODE

ODE

ODE

ODE”””” will be shown first. Do NOT

NOT

NOT

NOT enter CCCCODE

ODE

ODE

ODE Setup Mode. Use the arrow keys to 

move past CODE

CODE

CODE

CODE and VOL

VOL

VOL

VOL Modes to DATE

DATE

DATE

DATE Mode, then press TARE/PRESET

TARE/PRESET

TARE/PRESET

TARE/PRESET to display the current date. Date format is yy.mm.dd. If 

you enter the wrong mode, press the    HOLD

HOLD

HOLD

HOLD/SETUP

/SETUP

/SETUP

/SETUP    key to return to the previous menu, or press    ZERO/ON/OFF

ZERO/ON/OFF

ZERO/ON/OFF

ZERO/ON/OFF to exit setup. 

4.

 

Press the UNIT/DATA

UNIT/DATA

UNIT/DATA

UNIT/DATA    key for 4 seconds to enter date modification mode. Use the arrow keys to modify the date. If no entry is made 

within 5 seconds, it will automatically exit modification mode. 

5.

 

Press the    HOLD

HOLD

HOLD

HOLD/SETUP

/SETUP

/SETUP

/SETUP    key to return to the previous menu and use the arrow keys to move to TIME

TIME

TIME

TIME Mode, then press 

TARE/PRESET

TARE/PRESET

TARE/PRESET

TARE/PRESET to display the current time. Time format is hh.mm.ss as a 24 hour format.   

6.

 

Press the UNIT/DATA

UNIT/DATA

UNIT/DATA

UNIT/DATA    key for 4 seconds to enter time modification mode. Use the arrow keys to modify the time. If no entry is made 

within 5 seconds, it will automatically exit modification mode. 

7.

 

Press the    HOLD

HOLD

HOLD

HOLD/SETUP

/SETUP

/SETUP

/SETUP    key to return to the previous menu and use the arrow keys to move to VER

VER

VER

VER Mode. Press TARE/PRESET

TARE/PRESET

TARE/PRESET

TARE/PRESET to 

view the software version. Firmware version format is Vxx.yy, where xx is the hardware version, and yy is the software version. 

8.

 

Press    ZERO/ON/OFF

ZERO/ON/OFF

ZERO/ON/OFF

ZERO/ON/OFF to exit setup. 

 
 

MISC Submenu:

MISC Submenu:

MISC Submenu:

MISC Submenu:    

SUB

SUB

SUB

SUB----    

MENU1

MENU1

MENU1

MENU1    

REMARK

REMARK

REMARK

REMARK

 

CODE

 

Displays the ADC (Analog to Digital Converter) code.    ADC setting to be adjusted by a technician only. 

VOL

 

Displays battery voltage.    Normal battery range is 5.6V-7.6V.    Replace batteries if below 5.6V. 

DATE

 

Displays and sets the date 

TIME

 

Displays and sets the time

 

VER

 

Displays firmware version

 

    

Summary of Contents for TEI

Page 1: ...TEI Operation Manual Contents subject to change without notice Version 1 1 5 2020...

Page 2: ...Mode Counting Mode 6 Percent Weighing Mode Percent Weighing Mode Percent Weighing Mode Percent Weighing Mode 7 Set Set Set Setup Mode up Mode up Mode up Mode 8 Calibration Mode Calibration Mode Calibr...

Page 3: ...nterface Interface Interface RS232 COM1 and USB COM2 Feet Feet Feet Feet 4 x fixed bolt design adjustable height Max Max Max Max Overload Overload Overload Overload 120 of capacity P P P Plllla a a at...

Page 4: ...data entry position by one Menu selection mode Goes to next item of current sub menu UNIT UNIT UNIT UNIT DATA DATA DATA DATA Weighing mode 3 seconds Changes weighing unit of measure Counting or Perce...

Page 5: ...on the display 3 Put the material or object to be weighed in the container The net weight will be displayed 4 To exit tare mode remove all weight from the scale The display will show a negative weight...

Page 6: ...ched within the stabilization time default of 9 seconds the scale will display STB ER STB ER STB ER STB ER Press the TARE PRESET TARE PRESET TARE PRESET TARE PRESET key to HOLD HOLD HOLD HOLD again or...

Page 7: ...ck Weighing Data Compare Data Compare Data Compare Data Compare Mode Mode Mode Mode The check weighing or data compare function allows the user to input a pre set range and the display will indicate w...

Page 8: ...e If the input piece weight is less than 0 5d where d the scale s readability see specifications the indicator will display PWt Er PWt Er PWt Er PWt Er and will automatically return to counting mode b...

Page 9: ...he HOLD HOLD HOLD HOLD SETUP SETUP SETUP SETUP key for 4 seconds to input the decimal point Press the TARE PRESET TARE PRESET TARE PRESET TARE PRESET key to confirm and return to percent weighing mode...

Page 10: ...USER USER USER Setup mode If you enter the wrong mode press the HOLD HOLD HOLD HOLD SETUP SETUP SETUP SETUP key to return to the main menu or press ZERO ON OFF ZERO ON OFF ZERO ON OFF ZERO ON OFF to...

Page 11: ...O COUNT YES Yes No enable disable output counts Prompt is QUANTITY NO NO PCWT YES Yes No enable disable output piece weight Prompt is PIECE WT NO NO BMI YES Yes No enable disable output height and BMI...

Page 12: ...2 output mode 1 NONE No communication 2 CONT Continuous output 3 PRINT Output when PRINT FUNC PRINT FUNC PRINT FUNC PRINT FUNC key is pressed scale must be stable 4 CMD Output when a request command i...

Page 13: ...NO COUNT YES Yes No enable disable output counts Prompt is QUANTITY NO NO PCWT YES Yes No enable disable output piece weight Prompt is PIECE WT NO NO BMI YES Yes No enable disable output height and BM...

Page 14: ...ative value relative to the last zeroed value TOGGLE 4 TOGGLE Press HOLD key to hold the data as long as weight is over NLD RNG and stable Press HOLD key again to exit AVERAG 5 AVERAG Average HOLD If...

Page 15: ...cuted 4 COM 1 2 command from COM1 or COM2 will be executed COM 1 COM 1 COM 2 COM 1 2 A OFF T 0 255 Auto off time 0 no auto power off 1 255 auto off after 1 255 minutes of no operation or weight change...

Page 16: ...Use the arrow keys adjust the input value to the standard calibration weight you will use Note Note Note Note do not use less than 10 of the scale s rated capacity do not use less than 10 of the scale...

Page 17: ...cale s capacity END Y YES End calibration YES go to CAL END NO go to next point calibration NO CAL P2 Linear calibration point 2 does second weight point calibration Standard weight should be more tha...

Page 18: ...TARE PRESET TARE PRESET key Use the arrow keys to select the geographic adjustment code for your location 00 70 using Table 1 Press TARE PRESET TARE PRESET TARE PRESET TARE PRESET key to confirm Note...

Page 19: ...setup 4 Press the UNIT DATA UNIT DATA UNIT DATA UNIT DATA key for 4 seconds to enter date modification mode Use the arrow keys to modify the date If no entry is made within 5 seconds it will automatic...

Page 20: ...llowed the first digit for positive Decimal point 1byte Measure unit 1 5bytes lb kg lb oz pcs units are always lower case and left aligned Current status 4bytes If over capacity the scale will return...

Page 21: ...re The details of Prompt refer to the content in User Setup User Setup User Setup User Setup submenu In hold mode if the A D conversion speed is set to high 80Hz and USER USER USER USER COM1 2 COM1 2...

Page 22: ...E PRESET TARE PRESET TARE PRESET to enter Either rd1 rd1 rd1 rd1 or td1 td1 td1 td1 or rd2 rd2 rd2 rd2 or td2 td2 td2 td2 will be displayed Note Note Note Note A cable must connect the indicator to a...

Page 23: ...sure Weight reading below minimum load limit Install platform on scale Perform zero calibration EEP E2 EEP E2 EEP E2 EEP E2 USER parameters are not correctly set Re set settings in USER mode CAL Er CA...

Page 24: ...Character Definitions Definitions Definitions Definitions Packing Packing Packing Packing Content Content Content Contents s s s Indicator w tilting bracket Scale platform base AC120V DC6V 500mA UL ad...

Page 25: ...23 Totalcomp Inc 99 Reagent Lane Fair Lawn NJ 07410 Tel 800 631 0347 Fax 888 797 2287 www Totalcomp com...

Reviews: