HAND-HELD SHOWER OPERATION

1. With the water on, push the diverter button down. Water will be diverted from the spout to the hand-held shower.

2. To adjust the spray setting, turn the control ring located on the outer edge of the shower head.

3. To divert the water back to the spout, simply turn off the water supply.  When you turn the water back on, the water

will automatically flow out of the spout.

HYDROTHERAPY SYSTEM OPERATION

:

 

1.

To operate the

 Air Massage System

 

with the 3-speed variable motor, 

push the button labeled 

AIR

 to turn

on the

 

system. It automatically starts at the highest setting.  Push it again for the medium setting. The third

push

 

is the low setting.  The fourth push will shut off the system.

Jets run for 20 minutes then automatically shut off.

Blower is equipped with purging/drying cycle that will start 20 minutes after use and will continue

for several minutes.

2.

To operate the 

Whirlpool System

, push the button labeled 

W

ATER

 to turn the system on.  Push the

button again to turn the whirlpool system off.

Ensure the water level is above all the jets for the jets to function correctly.

Damage to the jets and pump can occur if you attempt to operate the whirlpool system without

water.

The heat exchanger automatically maintains your water temperature when your whirlpool system

 

is

operating.

Water will drain out of the whirlpool system after each use.

3.

The 

Ozone Sanitation System

 works automatically with your Whirlpool System.

Ozone gas introduced into the water helps to sanitize your whirlpool system from material such as

soaps and body oils that may be found in your bath water and plumbing.

When your Whirlpool pump is on, the system immediately generates ozone gas that is mixed in

with your circulating bathwater.

When the Whirlpool pump is turned off, the ozone system automatically turns off.

4.

Operating your 

Bidet Jet 

for personal hygiene

:

Turn on your

whirlpool system

 by pushing the button labeled 

WATER

.

Turn the knob labeled 

BIDET

 counter-clockwise (to the left) to increase the strength of the jet.

To decrease the strength, turn the knob clockwise (to the right).

5.

Operating your massaging 

Back Hydrotherapy Jets:

Turn on your whirlpool system by pushing the button labeled 

W

ATER

.

Turn the knob labeled 

BACK JET

 counter-clockwise (to the left) to increase the strength of the

back jets.

Turn the knob clockwise (to the right) to decrease the strength of the jets.

Summary of Contents for 2852FL

Page 1: ...Total Care In Bathing INSTALLATION OPERATING INSTRUCTIONS Model 2852FL To be provided to the owner user CUSTOMER SERVICE Contact Customer Service at 866 292 5546 Monday Friday 8 00 5 00 PST FL TUB Ma...

Page 2: ...ll allow Hydro Dimensions to process any warranty claims PURCHASE REGISTRATION The information provided on the Product Registration Card will be kept on file with Hydro Dimensions as official purchase...

Page 3: ...____ You are aware that the door must remain open when the tub is not in use to maintain the integrity of the door seal ______ You have read the owners manual and understand how to operate and maintai...

Page 4: ...Page 4 of 16 FL TUB Revision 1 26 2018 This page intentionally left blank...

Page 5: ...operate electrically connected devices in or near the bath No electric appliances should be within 5 feet 1 5 meters of this bathtub hair dryers lamp telephone radio television etc F Never drop or in...

Page 6: ...5 minutes and are recommended for younger children the elderly and frail If you become nauseous dizzy or develop a headache you may be experiencing Hyperthermia an unsafe increase in your core body te...

Page 7: ...surface in an area where it may be drained after testing 3 Never lift the tub by any portion of the hydro massage system 4 Adjust the drain stopper so it seats completely when down and raises AT LEAST...

Page 8: ...nly for 60 installations 5 The door drain assembly is attached at one end at the factory The drain body is to be installed between the drain shoe and the drain tee NOTE The drain body and hose must be...

Page 9: ...Page 9 of 16 FL TUB Revision 1 26 2018...

Page 10: ...tly under pressure from a completely full tub POST INSTALL CLEANING WARNING Under no circumstances use wire brushes metal sponges knives steel wool or scouring pads on any part of the tub Do not use s...

Page 11: ...or oily types other than the automatic dish detergent used for cleaning the whirlpool system 6 There is a risk of hyperthermia and drowning with prolonged immersion and or excessive water temperature...

Page 12: ...e jets to function correctly Damage to the jets and pump can occur if you attempt to operate the whirlpool system without water The heat exchanger automatically maintains your water temperature when y...

Page 13: ...isplayed LED FAUCET LIGHTS if you have this option installed The LED faucet lights work automatically with your chromatherapy system AROMATHERAPY OPERATION To operate your Aromatherapy simply unscrew...

Page 14: ...TANT to wipe down the door seal and doorjamb after each use in order to maintain the integrity of the water seal In order to keep the door seal and doorjamb clean and not accumulate dirt or debris of...

Page 15: ...not secure when draining the tub as the water level lowers the pressure on the door will be reduced thus increasing the possibility of a leak around the door 4 Leave the tub door open when not in use...

Page 16: ...lteration or modification chemical corrosion or improper maintenance There will be a charge for replacement parts or replacement of the entire electrical unit if the defective unit is returned for any...

Reviews: