PIREG 545 cUL Operators Guide 2021
34
Settings Menu 113 – Batch
Counter Reset
SETTINGS 113
Batch counter
Reset with ENTER
Setting menu 113 is used to reset the Batch Counter displayed on
the Home Screen only with Batch Counter set to “On” in Configura-
tion menu 226.
Press the Enter button
≡
to reset the batch counter to zero.
Press the Menu Scroll
to advance back to the Home Screen.
6.4. Configuration-menu
Advancing to the Configuration menus:
From the Home Screen, hold the Menu Scroll button
for
longer than 2s to change to the Configuration menus. Then press the Menu Scroll button
to advance
through the various Configuration menus.
Configuration Menu 201 -
Language
CONFIGURATION 201
Language: english
D–E–FR–IT-SP-Py
Configuration menu 201 is used to select the display language (Ger-
man (D), English (E), French (FR), Italian (IT), Spanish (SP), and
Russian (Py).
Press the
buttons to select the language and accept by press-
ing the Enter button
≡
. Press the Menu Scroll
to advance to Con-
figuration menu 202.
Configuration Menu 202 – Re-
call / Save Settings
CONFIGURATION 202
Factory settings:
Recall factory
settings
Configuration menu 202 is used for:
- Recall factory settings –
recalls all configuration settings as re-
ceived from the TOSS factory.
- Save customer settings –
Allows machine builder to save all con-
figuration settings custom to the specific OEM equipment.
- Recall customer settings –
Restores saved OEM equipment set-
tings.
Note:
To clear the saved customer setting press the combi-
nation
+
+
≡
for 2 seconds.)
Press the
buttons to select the desired function and accept by
pressing the Enter button
≡
. Press the Menu Scroll
to advance to
the Configuration Menu 203.
Configuration Menu 203 – Al-
loy Tc Selection / ppm
CONFIGURATION 203
Temperature coeffi-
cient: 1235ppm
e.g. Alloy-A20C
Configuration menu 203 is used for the selection of the heat seal
band Alloy. There are four (4) fixed Alloy/Tc-settings and a “variable’
Tc-settings.
The fixed Alloy/Tc-settings selections are:
1.) Alloy L - 746ppm
2.) Alloy A20K - 862ppm
3.) Alloy A20C - 1235ppm
4.) Norex - 4830ppm
If a fixed Alloy/Tc-setting is selected, pressing the Menu Scroll
will
advance to the next Configuration menu 205.
5.) “variable” Tc-settings – 400…2200ppm
Note:
If the “variable” Tc-setting is selected with Advanced PIREG
®
features
OFF
(Configuration 227) pressing the Menu Scroll
will
advance to the next Configuration menu 204.
Note:
If the “variable” Tc-setting is selected with Advanced PIREG
®
features
ON
(Configuration 227), at the selection of the “variable” Tc
settings the text “variable / (Tc1, Tc2 & Tc3)” is displayed. Pressing
the Menu Scroll
to advance to the Configuration menu 204a.