26
(2). Instructions to the Error Indicating Lamps on the Panel of the Floor Ceiling Type Unit.
States of the Indicating Lamps:
① .
Indicating Lamp of “POWER”: The indicating lamp will
shine when power on, while it will go out when power off.
② .
Indicating Lamp of “COOL” :
The indicating lamp will shine when “COOL” is activated,
while it will go out when “COOL” is deactivated.
③ .
Indicating Lamp of “HEAT”:
The indicating lamp will shine when “HEAT” is activated,
while it will go out when “HEAT” is deactivated.
④ .
Indicating Lamp of “TIMER”:
The indicating lamp will shine when “TIMER” is activated,
while it will go out when “TIMER” is deactivated or the set.
①
②
④
③
Fig.37
6.2 Working Temperature Range
Table 11
Test Condition
Indoor Side
Outdoor Side
DB(°C)
WB(°C)
DB(°C)
WB(°C)
Nominal Cooling
27
19
35
24
Nominal Heating
20
−
7
6
Rated Cooling
32
23
48
−
Low Temp. Cooling
21
15
-15
−
Rated Heating
27
−
24
18
Low Temp. Heating
20
−
-
2
0
-
20.5
Note:
① .
The design of this unit conforms to the requirements of EN14511 standard.
② .
The air volume is measured at the relevant standard external static pressure
.
③ .
Cooling (heating) capacity stated above is measured under nominal working conditions
corresponding to standard external static pressure.
The parameters are subject to change with
the improvement of products, in which case the values on nameplate shall prevail.
④ .
In this table, there are two outside DB values under the low temp cooling conditions, and the
one in the brackets is for the unit which can operate at ex
treme low temperature.