background image

9

I FEEL


Notice

CLOCK

SLEEP

After starting up T-ON or T-OFF,set the constant cir-

culating valid.
After that,air conditioner will be turned on or turned off

according to setting time.ON/OFF button has no effect

on setting.If you don’t need this function, please use r-

emote controller to cancel it.

 

Clock time adopts 24-hour mode.

 

The interval between two operations can

'

t exceed 5s. 

Otherwise, remote controller will quit setting status. 
Operation for TIMER ON/TIMER OFF is the same.

Press this button to start I FEEL function and "      " 

will be displayed on the remote controller. After this

function is set, the remote controller will send the 

detected ambient temperature to the controller 

and the unit will automatically adjust the indoor te-

mperature according to the detected temperatu

 

re. 

Press this button again to cancel I FEEL function 

and "      " will disappear. 

Please put the remote controller near user when

 

 this

function is set. Do not put the remote control

 

ler 

near the object of high temperature or low temper-

ature in order to avoid detecting inaccurate amb

 

ie-

nt temperature.When I FEEL function is turned on, 

the remote controller should be put within the a

 

rea 

where indoor unit can receive the signal sent by

 

 

 the 

remote controller. 

WiFi

Press this button, can select Sleep 1 (     1),

Press this button to set clock time. "      " icon on 

remote controller will blink. Press "

" or "  

  " 

button within 5s to set clock time. Each pressing 

of "

" or "   

 " button, clock time will increas

 

e or 

decrease 1 minute.If hold "

" or "    

" button

 

, 2s 

later, time will change quickly. Release this button 

when reaching your required time. Press "CLOCK" 

button to confirm the time. "     " icon stops blinking.  

Sleep 2 (      2), Sleep 3 (      3) and cancel the 

Sleep, circulate between these, after electrified, 

Sleep Cancel is defaulted.

Sleep 1 is Sleep mode 1, in Cool modes; sleep

setting temperature.

Sleep 2 is sleep mode 2, that is air conditioner

Sleep 3-the sleep curve setting under Sleep

will run according to the presetting a group of 

sleep temperature curve.

status after run for one hour, the main unit setting 

temperature will increase 1 , two hours, setting 

temperature increased 2

, then the unit will run at

this setting temperature; In Heat mode: sleep 

status after run for one hour, the setting tempera- 

ture will decrease 1 , two hours, setting tempera-

ture will decrease 2 , then the unit will run at this 

When WiFi function is turned on, " WiFi " icon will

be displayed on the remote controller; when WiFi

function is turned off, " WiFi " icon will disappear.

How to turn on WiFi

Press " WiFi " button to turn

on WiFi function.

How to turn off WiFi

Hold " WiFi " button for 5s to

turn off WiFi function.

Under off status, press "MODE" and " WiFi " buttons 

simultaneously for 1s, WiFi module will

restore factory settings.
This function is only available for some models.

Sleep3- the sleep curve setting under Sleep

mode by DIY could be inquired:

mode by DIY;

(1)Under Sleep 3 mode, press “Turbo” button for a 

long time, remote controller enters into user indi-

viduation sleep setting status, at this time, the time 

of remote controller will display “1hour”, the setting 

temperature “88” will display the corresponding 

temperature of last setting sleep curve and blink 

(The first entering will display according to the 

initial curve setting value of original factory);

(2)Adjust “+” and “-” button, could change the 

corresponding setting temperature, after adjusted, 

press “Turbo” button for confirmation;

(3) At this time,  1hour will be automatically 

increased at the timer position on the remote con-

trol, (that are "2hours" or "3hours" or "8hours"), the 

place of setting temperature "88" will display the 

corresponding temperature of last setting sleep 

curve and blink;

(4) Repeat the above step (2)~(3) operation, until 

8 hours temperature setting finished, sleep,curve 

setting finished, at this time, the remote controller 

will resume the original timer display; temperature 

display will resume to original setting temperature.

The user could accord to sleep curve setting 

method to inquire the presetting sleep curve, enter 

into user individuation sleep setting status, but do 

not change the temperature, press "Turbo" button 

directly for confirmation. Note: In the above preset-

ting or enquiry procedure, if continuously within 

10s, there is no button pressed, the sleep curve 

setting within 10s, there is no button pressed, the 

sleep curve setting status will be automatically quit 

and resume to display the original displaying. In 

the presetting or enquiry procedure,  press 

"ON/OFF" button, "Mode" button, "Sleep" button, 

the sleep curve setting or enquiry status will quit 

similarly.

Summary of Contents for GWH09AGA-K6DNA1A

Page 1: ...aintenance Installation notice Installation of indoor unit Test and operation Configuration of connection pipe Owner s Manual Original Instructions Split Air Conditioner Thank you for choosing our product Please read this Owner s Manual carefully before operation and retain it for future reference Notice Actual product may be different from graphics please refer to actual products ...

Page 2: ...GWH09AGA K6DNA1A I GWH09AGB K6DNA1B I GWH12AGB K6DNA1A I GWH12AGC K6DNA1A I GWH18AGD K6DNA1A I ...

Page 3: ...g reasons This symbol indicates the possibility of death or serious injury This symbol indicates the possibility of injury or damage to property Indicates important but not hazard related information used to indicate risk of property damage If it needs to install move or maintain the air conditioner please contact dealer or local service center to conduct it at first Air conditioner must be instal...

Page 4: ...lification for using the flamm able refrigerant It can only be repaired by the method suggested by the equipment s manufacturer including children with reduced physical sensory or mental capabilities or lack of expe d n a e c n e i r knowledge unless they have been given superv ision or instruction concerning use of the applia nce by a person responsible for their safety Children should be supervi...

Page 5: ...gerant If you should cut or weld the refrigerant system pipes in the process of maintaining please foll ow the steps as below c Vacuuming d e Cutting or welding Clean it with N2 gas f Carry back to the service spot for welding Filling the refrigerant The refrigerant should be recycled into the sp ecialized storage tank Make sure that there isn t any naked flame ne ar the outlet of the vacuum pump ...

Page 6: ...air conditioner Unstable power supply or incorrect wiring may result in electric shock fire haza rd or malfunction Please install proper power supply cables before using the air conditioner The grounding resistance should comply with nation al electric safety regula tions Air Conditioner should be properly grounded Inco rrect grounding may cause electric shock Do not put through the power before f...

Page 7: ... must be po sitioned so that the plug is accessible For the air conditioner with plug the plug should be re achable after finishing in stallation For the air conditioner with out plug a circuit breaker must be installed in the line The yellow green wire in air conditioner is ground ing wire which can t be us ed for other purposes The air conditioner is the first class electric applian ce It must b...

Page 8: ... by the manufacturer its ser vice agent or similarly qua lified persons in order to avoid a hazard Do not connect air condi tioner to multi purpose soc ket Otherwise it may cau se fire hazard Do disconnect power supp ly when cleaning air condi tioner Otherwise it may cause electric shock Do not wash the air condi tioner with water to avoid electric shock Do not spray water on in door unit It may c...

Page 9: ...t It may cause mal function Do not step on top panel of outdoor unit or put heavy objects It may cause dam age or personal injury When below phenomenon occurs please turn off air conditioner and disconnect power immediately and then contact the dealer or qualified professionals for service Power cord is overheat ing or damaged There s abnormal sound during operation Circuit breaker trips off frequ...

Page 10: ... turn off the air conditioner When the air conditioner is turned on it will operate under auto mode Display Temp indicator Power indicator This is the general introduction and the color of indicator is only for reference Please refer to the actual display Display content may be different from the actual Please refer to the actual display 5 air inlet filter panel Notice upper air guide louver lower...

Page 11: ...o mode Send signal Auto mode Cool mode Operation mode Set time TIMER ON TIMER OFF Left right swing Up down swing Child lock Dry mode Fan mode Heat mode I feel Set fan speed Temp display type Introduction for icons on display screen Buttons on remote controller Operation and introduction of remote controller TURBO FAN MODE ON OFF I FEEL T ON T OFF TEMP CLOCK LIGHT WiFi SLEEP ...

Page 12: ...gle Cooling only unit won t receive heating mode signal If setting heat mode with remote controller press ON OFF button can t start up the unit Press this button to turn on the unit Press this button again to turn off the unit AUTO COOL DRY FAN HEAT Press this button to select your required operation mode MODE ON OFF When selecting auto mode air conditioner will operate automatically according to ...

Page 13: ...ust the clock time Press or button once increase or decr ease set temperature 1 F Holding or button 2s later set temperature on remote controller will change quickly On releasing button after setting is finished temperature indicator on indoor unit will change accordingly When setting T ON T OFF or CLOCK press or button to adjust time Refer to CLOCK T ON T OFF buttons Notice no display stops at cu...

Page 14: ...eat mode sleep status after run for one hour the setting tempera ture will decrease 1 two hours setting tempera ture will decrease 2 then the unit will run at this When WiFi function is turned on WiFi icon will be displayed on the remote controller when WiFi function is turned off WiFi icon will disappear How to turn on WiFi Press WiFi button to turn on WiFi function How to turn off WiFi Hold WiFi...

Page 15: ...ction Under 8 heating function fan speed is defaulted at auto speed and it can t be adjusted Under 8 heating function set temperature can t be adjusted Press TURBO button and the remote controller won t send signal Sleep function and 8 heating function can t operate at the same time If 8 heating function has been set under heat mode press sleep button will cancel 8 heating function If sleep functi...

Page 16: ...wn in Fig 1 Place two 7 AAA 1 5V dry batteries and make sure the position of polar and polar is correct as shown in Fig 2 Notice This function is only available for some models Under unit off status hold Mode and Fan buttons simultaneously for 5s to turn on or turn off the auto clean function When the auto clean func tion is turned on indoor unit displays CL During the auto clean process of evapor...

Page 17: ...ed Check whether air switch plug and socket are Many packing materials are recyclable mate Check whether mounting bracket for outdoor unit is damaged or corroded If yes please contact dealer 5 Check whether drainage pipe is damaged in good condition Check whether filter is clean Check whether mounting bracket for outdoor unit is damaged or corroded If yes please contact dealer The filter should be...

Page 18: ...eck the batteries If the power of batter s e i o l is too w please rep lace them Under heating mode indoor temperature is reached to set temp erature Power failure Is plug loose In order to prevent blowing out cold air indoor unit will be started after delaying for several minutes which is a normal phenomenon Wiring has malfunc tion Unit has restarted immediately after stopping operation Wait for ...

Page 19: ... system pre ssure rise or compressor rupture resulting in injury Measuring tape spanner Inner hexagon When installing or moving this unit do not charge the refrigerant which is not comply with that on the nameplate or unqualified refrigerant Otherwise it may cause abnormal operation wrong action mechanical malfunction or even serious safety accident sure that the unit is running in cooling mode Th...

Page 20: ...the requirement of air conditioner Unstable power supply or incorrect wiring or malfunction Pl ease install proper power supply cables before using the air conditioner grounding wire of power socket 5 Be sure to cut off the power supply before pr oceeding any work related to electricity and safety 8 2 Select a location where the condensation water 3 Select a location which is convenient to conne c...

Page 21: ...sures when opening the hole bellmouth Pretighten the union nut with hand Please refer to the actual circumstances for the number of screws and the position of screws rear right 1 16 The pipe can be led out in the direction of right Choose the position of piping hole according Adjust the torque force by referring to the wrench on the union nut Tighten the union nut with torque wrench When installat...

Page 22: ...sulating pipe insulating pipe drain hose Make the power connection wire go through the cable cross hole at the back of indoor unit and then pull it out from the front side panel screw wiring cover outlet pipe drain hose All wires of indoor unit and outdoor unit should be If the length of power connection wire is insufficient For the air conditioner with plug the plug should be Notice Step 7 Connec...

Page 23: ... to the wiring terminal according to the color tighten the screw and then fix the po wer connection wire with wire clip 18 Bind them evenly The liquid pipe and gas pipe should be bo und separately at the end Bind up the connection pipe power cord and drain hose with the band connection pipe drain hose band indoor power cord Reserve a certain length of drain hose and power cord for installation whe...

Page 24: ...lfunction or damage the parts Is there any obstruction in the air inlet and outlet Is heat insulation of pipe line sufficient It may cause malfunction or damage the parts The gas valve and liquid valve of connection pipe are open completely The dust and sundries caused during installation are removed It may cause condensation and water dripping It may cause electric leakage Is the inlet and outlet...

Page 25: ...ndard connec tion pipe of 7 5m and 8m the min length of con nection pipe is 3m Max length of connection pipe is shown as below 4 1 2 The calculation method of additional refrigerant oil and refrigerant charging amount after prolong ing connection pipe After the length of connection pipe is prolonged for 10m at the basis of standard length you should add 5ml of refrigerant oil for each additional 5...

Page 26: ...urface improper expanding the length is equal leaning damaged crack surface uneven thickness expander pipe hard mold Notice A mm Max Min Φ6 6 35 1 4 1 3 0 7 Φ9 52 3 8 1 6 1 0 Φ12 12 7 1 2 1 8 1 0 Φ15 8 16 5 8 2 4 2 2 Outer diameter mm B Remove the burrs D Put on the union nut E Expand the port F Inspection shaper downwards pipe A is different according to the diameter please refer to the sheet bel...

Page 27: ...eal ed or intrinsically safe Presence of fire extinguisher If any hot work is to be conducted on the refrigera tion equipment or any associated parts appropriate Ventilated area Ensure that the area is in the open or that it is ad equately ventilated before breaking into the system or conducting any hot work A degree of ventilation shall continue during the period that the work is carri ed out The...

Page 28: ...e and being used correctly the recovery process is supervised at all times by a competent person d Pump down refrigerant system if possible e If a vacuum is not possible make a manifold so that refrigerant can be removed from various parts of the system f Make sure that cylinder is situated on the scales before recovery takes place g Start the recovery machine and operate in accor dance with manuf...

Page 29: ...d refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder and the relevant waste transfer note arranged Do not mix refrigerants in recovery units and especially not in cylinders If compressors or compressor oils are to be remov ed ensure that they have been evacuated to an ac ceptable level to make certain that flammable refri gerant does not remain within the lu...