background image

Owner’s Manual

English

Wireless remote controller kit

Model name:

RBC-AX32CE2

Generic model name

Wireless remote controller 
model name

RBC-AX32CE2

WH-L11SE

Signal receiving unit 
model name

SX-W3NE

AIR CONDITIONER (SPLIT TYPE)

Owner’s Manual

+00EB01700201.BOOK  Page 1  Wednesday, September 28, 2011  10:22 AM

Summary of Contents for WH-L11SE

Page 1: ... kit Model name RBC AX32CE2 Generic model name Wireless remote controller model name RBC AX32CE2 WH L11SE Signal receiving unit model name SX W3NE AIR CONDITIONER SPLIT TYPE Owner s Manual 00EB01700201 BOOK Page 1 Wednesday September 28 2011 10 22 AM ...

Page 2: ...ler 13 10 Before asking for repair work 14 Thank you very much for purchasing TOSHIBA Remote controller for Air Conditioner Please read this owner s manual carefully before using your Remote controller for Air Conditioner Be sure to obtain the Owner s manual and Installation manual from constructor or dealer Request to constructor or dealer Please clearly explain the contents of the Owner s manual...

Page 3: ...continuously operated with something abnormal it may cause machine failure electric shock fire or other trouble Reinstallation and repair Do not repair any unit by yourself Whenever the air conditioner needs repair make sure to ask the dealer to do it If it is repaired imperfectly it may cause electric shock fire or other trouble When reinstalling the air conditioner contact with the dealer If the...

Page 4: ...ir conditioner is in use or not Initial setting When batteries are inserted in the remote controller the clock panel will indicate AM 0 00 and will flash 1 TIMER or button Push the TIMER or button to set the current time Each push of the TIMER button changes the time in one minute steps Pushing the TIMER button continually changes the time in ten minute steps 2 SET button Push the SET button The c...

Page 5: ...ard Push the SWING button to stop the louver swinging A receiving beep is heard 7 Set louver button FIX Push this button to adjust the airflow direction A receiving beep is heard It cannot be operated by holding down the button Push the button with some interval 8 Off timer button OFF Push this button to set the OFF timer 9 On timer button ON Push this button to set the ON timer 10Reserve button S...

Page 6: ...display Indicates the current operation mode A Auto changeover control Cool Dry Heat Fan only 3 Temperature display Indicates the temperature setting 17 C to 30 C When you set the operating mode to Fan only no temperature setting is indicated 4 FAN speed display Indicates the selected fan speed AUTO or one of five fan speed levels LOW LOW MED MED HIGH can be indicated Indicates when the operating ...

Page 7: ...t The signal sent from the remote controller is received 3 Display lamp One of displays flashed while a trouble occurs When the display lamp flashes refer to Before asking for repair work 4 lamp Green This lamp goes on during operation 5 lamp Green This lamp goes on while the timer is reserved 6 lamp Orange In heating operation this lamp in the following cases The operation has started The temp co...

Page 8: ... Start 1 START STOP button Push this button to start the air conditioner 2 Mode select button MODE Select A 3 Temperature button Set the desired temperature 4 Fan speed button FAN Set a desired fan speed Five patterns are displayed but LOW is equal to LOW and MED to MED The OPERATION lamp green on the display lamp of the signal receiving unit lights The operating mode is selected in accordance wit...

Page 9: ...oner does not automatically control the room temperature Quiet operation The QUIET mode provides quiet operating status by automatically setting the fan speed to the lowest speed Setting QUIET mode 1 QUIET button Push the QUIET button after starting any operation At the same time the mark is indicated Cancelling QUIET mode 1 QUIET button Push the QUIET button once again At the same time the mark o...

Page 10: ...stment 1 Push the COMFORT SLEEP button Select 1 3 5 or 9 hours for the OFF timer operation CAUTION The COMFORT SLEEP mode is not enabled in the DRY or FAN ONLY operation When Auto changeover control mode is selected the air conditioner does not automatically control the room temperature Sleep timer operation To start the sleep timer OFF timer operation 1 Push the SLEEP button Select 1 3 5 or 9 hou...

Page 11: ...o not push the SET button within 30 seconds after setting the time the setting will be cancelled Once you select the timer operation mode the settings are saved in the remote controller Thereafter the air conditioner will start operating under the same conditions when you simply push the ON OFF button of the remote controller If the clock display is flashing you cannot set the timer Follow the ins...

Page 12: ...simultaneously and activate every day This feature is useful when you want to use combined timer at the same time every day Setting combined TIMER 1 Push the ON TIMER button to adjust the ON timer 2 Push the OFF TIMER button to adjust the OFF timer 3 Push the SET button 4 After step 3 an arrow mark or flashes for about 3 seconds and during this flashing push the SET button During the every day tim...

Page 13: ... SWING operation Stop the SWING operation before changing the louver angle Do not operate the air conditioner for long hours with the airflow direction set downward during the cooling or dry operation Otherwise condensation may occur on the surface of the vertical airflow louver and cause dew dripping 8 Mounting remote controller holder Direct the transmitter of the remote controller toward the si...

Page 14: ...ntrollers do not display A The factory default of the wireless remote controllers is A A B selection can be set with signal receiving unit For the further details refer to the installation manual 9 Operating air conditioner without remote controller In the following cases the air conditioner can be operate without remote controller with temporary operation button on the signal receiving unit The b...

Page 15: ...r switch is not turned on Turn on the power switch if it is off The air conditioner is in the ON timer operation Cancel the timer operation The batteries of the remote controller have been exhausted Replace the batteries The LEDs on the signal receiving unit are not in normal state or operation mode is not correct Change the operation mode Is not the sate of the display lamp Disagreement of cool a...

Page 16: ...EB01700201 1 00EB01700201 BOOK Page 15 Wednesday September 28 2011 10 22 AM ...

Reviews: