Table 1
1.
2.
Enter DATA SET mode by setting VOLUME to minimum.
Press both VOL. DOWN button on the set and Channel button (6) on the remote control for more than 2 seconds.
ADDRESS and DATA should appear as FIG 1.
Fig. 1
INIT 0B4 11
POWER ON 0010
PLAY/REC 0003
ADDRESS DATA
---
---
---
---
11
10
B0
92
C0
0C
+0
+1
+2
+3
+4
+5
+6
+7
+8
+9
+A
+B
+C
+D
+E
+F
INI
82
98
B2
D8
01
63
65
66
27
3A
0F
11
20
45
68
64
65
64
CA
00
DF
6F
F9
5F
01
FF
23
F9
6F
A0
20
08
BF
50
2B
B5
C1
41
9E
EF
C0
CF
B5
82
0B0
0C0
6B
18
3B
27
17
15
1B
0D0
00
37
87
0C
87
5F
0E0
9F
B2
9A
97
8C
B2
0F0
C4
00
34
13
13
77
40
27
47
55
00
00
00
00
00
00
00
03
04
27
40
20
A0
00
00
40
100
03
00
00
00
00
82
00
110
00
00
09
98
FF
01
If a service repair is undertaken where it has been required to change the MEMORY IC, the following steps should be taken to
ensure correct data settings while making reference to TABLE 1.
NOTE: Initial Data setting will not be possible if clock has been set. To reset clock, either unplug AC cord and allow
at least 30 minutes before Power On or alternatively, discharge backup capacitor.
No need setting for after INI 11F due to the adjustment value.
WHEN REPLACING EEPROM (MEMORY) IC
C4-1
4.
5.
6.
7.
8.
9.
10.
11.
12.
The unit will now have the correct DATA for the new MEMORY IC.
ADDRESS is now selected and should "blink". Using the UP/DOWN button on the remote, step through the ADDRESS
until required ADDRESS to be changed is reached.
Press ENTER to select DATA. When DATA is selected, it will "blink".
Again, step through the DATA using UP/DOWN button until required DATA value has been selected.
Pressing ENTER will take you back to ADDRESS for further selection if necessary.
Repeat steps 4 to 7 until all data has been checked.
When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.
After the data input, set to the initializing of shipping.
Turn POWER on.
Press both VOL. DOWN button on the set and Channel button (1) on the remote control for more than 2 seconds.
After the finishing of the initializing of shipping, the unit will turn off automatically.
Summary of Contents for VTW21FQR
Page 116: ......