TXZ Family
Flash Memory
2018-06-05
91 / 120
Rev. 2.0
6.6.2. Mode Setting
In order to execute the on-board programming, boot up this device in single boot mode. For details of single boot
mode setting, refer to “6.3 Mode Determination”.
6.6.3. Interface Specifications
This section describes the serial communication format in single boot mode. The serial operation mode supports
UART (asynchronous communication). In order to execute the on-board programming, set the communication
format of the programming controller as well.
Communication channel:
UART channel x (depends on the product)
Serial transfer mode:
UART (asynchronous communication) mode, half-duplex communication,
LSB-first
Data length:
8 bits
Parity bit:
None
STOP bit:
1 bit
Baud rate:
Arbitrary baud rate (Table 6.7 Setting of baud rate in Single boot mode
WDT:
Stops
The clock/mode control block setting of the internal boot program operates on the initial settings(fc=10MHz, Clock
are supplied to using function blocks).
A baud rate is determined by the 32-bit timer (T32A) mentioned in “6.6.6.1 Serial Operation Mode Determination”.
At this time, a baud rate needs to be within the measurable range by the timer.
The pins used in the internal boot program are shown in “Table 6.4
Pins used in the internal boot program”. Other
pins are not operated in the boot program.
Table 6.4 Pins used in the internal boot program
Category
Pin name
Mode setting pin
BOOT_N
Reset pin
RESET_N
Communication pins
UTxTXD
UTxRXD
Note1: UART channels to be used vary depending on the product. For details, refer to reference manual “Product
Information”.
Note2: When two UART pins exist in the same channel, either UART pin connected with the host device is
automatically detected at start-up in single boot mode (depending on the product). The RXD pin not
used in the channel is set to OPEN or fixed to “High” level. Do not connect both UART pins to the host
device at the same time.