TRANSPORTATION AND INSTALLATION MANUAL
STE80753
– 40 –
In the subsequent paragraphs, we explain how to connect cables
1
to
4
inclusive.
For information on how to connect cables
5
,
6
and
7
, refer to the Interface Manual.
4.1.2
Connecting the Power Cable “ACIN” (
1
of Fig. 4.1; plug connector attached)
The power cable is used to supply the main AC power to the controller.
Table 4.1 Power supply specifications
Item Specifications
Power supply
Single phase, AC 200 ~ 240 V, 50/60 Hz
±
1 Hz
Power capacity
4.4 kVA
Instantaneous power
failure
Within 40 msec
Grounding
JIS class D
The connector is ACIN (
1
of Fig. 4.1).
ACIN plug connector Type:
JL04V–6A22-22SE-EB-R
Maker: Japan Aviation
Electronics Industry
ACIN cable clamp
Type: JL04–2022CK (14)-R
Maker: Japan Aviation
Electronics Industry
Wire 3.5
mm
2
~ 5.5 mm
2
As the cable is not an accessory, use the attached plug connector connected to ACIN
on the controller side to manufacture a cable.
Wires are to be soldered to the connector.