3 Tests and Diagnostics
3.19 Hard Disk Test Detail Status
3-38
[CONFIDENTIAL]
TECRA M4 Maintenance Manual (960-521)
3.19 Hard Disk Test Detail Status
When an error occurs in the hard disk test, the following message is displayed:
HDC status = XXXXXXXX
Detailed information about the hard disk test error is displayed on the screen by an eight-
digit number. The first four digits represent the hard disk controller (HDC) error status
number and the last four digits are not used.
The hard disk controller error status is composed of two bytes; the first byte displays the
contents of the HDC status register in hexadecimal form and the second byte displays the
HDC error register.
The contents of the HDC status register and error register are listed in Tables 3-3 and 3-4.
Table 3-3 HDC status register contents
Bit Name
Description
7 BSY
(Busy)
“0” … HDC is ready.
“1” … HDC is busy.
6 DRY
(Drive ready)
“0” … Hard disk drive is not ready to accept any command.
“1” … Hard disk drive is ready.
5 DWF
(Drive write fault)
“0” … DWF error is not detected.
“1” … Write fault condition occurred.
4 DSC
(Drive seek complete)
“0” … The hard disk drive heads are not settled over a track.
“1” … The hard disk drive heads are settled over a track.
3 DRQ
(Data request)
“0” … Drive is not ready for data transfer.
“1” … Drive is ready for data transfer.
2 COR
(Corrected data)
“0” … Not used
“1” … Correctable data error is corrected.
1 IDX
(Index)
“0” … Not used
“1” … Index is sensed.
0 ERR
(Error)
“0” … Normal
“1” … The previous command was terminated with an error.
Summary of Contents for Tecra M4
Page 10: ...x CONFIDENTIAL TECRA M4 Maintenance Manual 960 521 ...
Page 11: ... CONFIDENTIAL Chapter 1 Hardware Overview ...
Page 12: ...1 Hardware Overview 1 ii CONFIDENTIAL TECRA M4 Maintenance Manual 960 521 1 Hardware Overview ...
Page 51: ...1 Hardware Overview 1 8 AC Adapter 1 36 CONFIDENTIAL TECRA M4 Maintenance Manual 960 521 ...
Page 52: ... CONFIDENTIAL Chapter 2 Troubleshooting ...
Page 53: ...2 Troubleshooting 2 ii CONFIDENTIAL TECRA M4 Maintenance Manual 960 521 2 ...
Page 57: ...2 Troubleshooting 2 vi CONFIDENTIAL TECRA M4 Maintenance Manual 960 521 ...
Page 114: ... CONFIDENTIAL Chapter 3 Tests and Diagnostics ...
Page 115: ...3 Tests and Diagnostics 3 ii CONFIDENTIAL TECRA M4 Maintenance Manual 960 521 ...
Page 119: ...3 Tests and Diagnostics 3 vi CONFIDENTIAL TECRA M4 Maintenance Manual 960 521 ...
Page 223: ...3 Tests and Diagnostics 3 30 SETUP 3 104 CONFIDENTIAL TECRA M4 Maintenance Manual 960 521 ...
Page 224: ... CONFIDENTIAL Chapter 4 Replacement Procedures ...
Page 225: ...4 Replacement Procedures 4 ii CONFIDENTIAL TECRA M4 Maintenance Manual 960 521 4 ...
Page 300: ...4 Replacement Procedures 4 29 Digitizer 4 70 CONFIDENTIAL TECRA M4 Maintenance Manual 960 521 ...
Page 320: ... CONFIDENTIAL Appendices ...
Page 321: ...Appendices App ii CONFIDENTIAL TECRA M4 Maintenance Manual 960 521 ...
Page 341: ...Appendices Appendix B Board Layout B 8 CONFIDENTIAL TECRA M4 Maintenance Manual 960 521 ...
Page 379: ...Appendices Appendix E Key Layout E 2 CONFIDENTIAL TECRA M4 Maintenance Manual 960 521 ...
Page 387: ...Appendices Appendix I Reliability I 2 CONFIDENTIAL TECRA M4 Maintenance Manual 960 521 ...