3.5 Memory Test
3 Tests and Diagnostics
TECRA M1 Maintenance Manual (960-436)
3-15
Subtest 04
Cache Memory
To test the cache memory, a pass-through write-read comparison of ‘5A’ data is
run repeatedly to the test area (‘7000’:‘Program’ size to ‘7000’:‘7FFF’ (32 KB))
to check the hit-miss ratio (on/off status) for CPU cache memory. One test takes 3
seconds.
Number of misses
<
Number of hits
→
OK
Number of misses
≥
Number of hits
→
Fail
Subtest 05
L2 Cache Memory
To test the L2 cache memory, a test similar to that for the cache memory is
performed.
Subtest 06
Stress
The conventional memory is provided with a write/read buffer (size 1b30 h) and
creates write data in the write buffer. Subsequent to 1 MB, the data is written in the
write buffer and is read into the read buffer, followed by a data comparison up to
the maximum memory size.
Summary of Contents for Tecra M1
Page 1: ...Toshiba Personal Computer TECRA M1 Maintenance Manual TOSHIBA CORPORATION File Number 960 436 ...
Page 6: ...vi TECRA M1 Maintenance Manual 960 436 ...
Page 10: ...x TECRA M1 Maintenance Manual 960 436 3 29 SETUP 3 78 ...
Page 13: ...TECRA M1 Maintenance Manual 960 436 xiii ...
Page 14: ...Chapter 1 Hardware Overview ...
Page 15: ...1 Hardware Overview 1 ii TECRA M1 Maintenance Manual 960 436 ...
Page 32: ...1 2 System Unit Block Diagram 1 Hardware Overview TECRA M1 Maintenance Manual 960 436 1 15 ...
Page 54: ...Chapter 2 Troubleshooting Procedures ...
Page 55: ...2 Troubleshooting Procedures 2 ii TECRA M1 Maintenance Manual 960 436 ...
Page 58: ...2 Troubleshooting Procedures TECRA M1 Maintenance Manual 960 436 2 v ...
Page 60: ...2 Troubleshooting Procedures TECRA M1 Maintenance Manual 960 436 2 vii ...
Page 123: ...Chapter 3 Tests and Diagnostics ...
Page 124: ...3 Tests and Diagnostics 3 ii TECRA M1 Maintenance Manual 960 436 ...
Page 224: ...3 Tests and Diagnostics 3 29 SETUP 3 96 TECRA M1 Maintenance Manual 960 436 ...
Page 225: ...Chapter 4 Replacement Procedures ...
Page 226: ...4 Replacement Procedures 4 ii TECRA M1 Maintenance Manual 960 436 ...
Page 309: ......
Page 327: ...4 Replacement Procedure 4 25 Fluorescent Lamp 4 90 TECRA M1 Maintenance Manual 960 436 ...
Page 330: ...4 25 Fluorescent Lamp 4 Replacement Procedure TECRA M1 Maintenance Manual 960 436 4 93 ...
Page 349: ...Appendices ...
Page 350: ...Appendices App ii ...
Page 362: ...Appendices Appendix A Handling the LCD Module A 6 TECRA M1 Maintenance Manual 960 436 ...
Page 368: ...Appendices Appendix B Board Layout B 6 TECRA M1 Maintenance Manual 960 436 F VR3000 Volume ...
Page 395: ...Appendices Apx C Pin Assignments C 24 TECRA M1 Maintenance Manual 960 436 123 NC 124 B3V ...
Page 401: ...Appendices Apx C Pin Assignments C 30 TECRA M1 Maintenance Manual 960 436 41 FL P5V ...
Page 408: ...Appendix C Pin Assignments Appendices TECRA M1 Maintenance Manual 960 436 C 37 ...
Page 418: ...Appendices Appendix E Key Layout E 2 TECRA M1 Maintenance Manual 960 436 ...
Page 422: ...Appendices Appendix G BIOS Rewrite Procedures G 2 TECRA M1 Maintenance Manual 960 436 ...
Page 424: ...Appendices Appendix H EC KBC Rewrite Procedures H 2 TECRA M1 Maintenance Manual 960 436 ...
Page 426: ...Appendices Appendix I Reliability I 2 TECRA M1 Maintenance Manual 960 436 ...