Page 15
· Remove the bucket from the unit, take down the pump and clean the filter of the pump.
· Check that the pump drain hose does not link or block.
· Empty the water of the bucket.
· Reinstall the pump hose if it drops and reinstall the bucket properly. Turn on the unit. If the error repeats, call
for service.
Note: Do not use this operation when the outdoor temperature is equal to or less than 0°C (32°F), otherwise
water is become ice that will cause the water hose blocked
up and the unit failure. Make sure to empty the bucket
once a week when using the pump draining feature. When
the pump draining feature is not being used, remove the
pump drain hose from the outlet. Press the pump drain
hose outlet in and take the pump drain hose out from it .
Make sure do not let the water in the pump hose drip to
the floor.
Note:
· Make sure the connection is tight and there is no leak.
· Lead the water hose to the floor drain or a suitable drainage facility, the drainage facility should be lower than
the drain outlet of the unit.
· Be sure to run the water hose sloping downward to let the water flow out smoothly.
· When the continuous drain feature is not being used, remove the drain hose from the outlet.
Filter of pump
2,Take the pump
drain hose out
1,Press the pump
drain hose outlet in