UP( )/DOWN( ) buttons
Page 13
Other features
Operating
Instructions
· Humidity Set Control buttons
· Press to initiate the Auto start or Auto stop feature,
in conjuction with the Up and Down buttons. When
the unit is on, press the Timer button to activate the
Auto stop feature. When the unit is off, press this
button to activate the Auto start feature.
· Press or hold the Up and Down button to change the
Auto time by 0.5 hour increments, up to 10 hours,
then at 1 hour increments up to 24 hours.
· The control will count down the time remaining until
start.
· The selected time will register in 5 seconds and the
system will automatically revert back to display the
previous humidity setting.
· Turning the unit ON or OFF at any time or adjusting
the timer setting to 0.0 will cancel the Auto start or
Auto stop feature.
· When LED display window displays the code of P2,
the Auto start or Auto stop feature will also be
cancelled.
· TIMER Set Control buttons
Press to initiate the Auto start and Auto stop feature,
in conjuction with the Up and Down buttons.
· Continuous Operation(On some models)
To run the unit in continuous mode, press the Down
button until the display reads 35% RH. Then press the
Down button again until the display reads “CO” for
continuous operation. To stop continuous operation,
press the Up button and set the desired % RH set point
level to resume nominal operation.
The humidity level can be set within a range of 35%
RH(Relative Humidity) to 85%RH(Relative Humidity)
in 5% increments.
For drier air, press the Down button and set to a lower
percent value(%).
For damper air, press the Up button and set a higher
percent value(%).
Bucket Full Light
Glows when the bucket is ready to be emptied, or
when the bucket is removed or not replaced in the
proper position.
Auto Defrost
When forst builds up on the evaporator coils, the
compressor will cycle off and the fan will continue to
run until the frost disappears.
proper position. When the setting humidity is reached,
the unit will be shut off automatically.
For some models, the fan motor will continue to run
for 30 seconds.
Auto Shut Off
The dehumidifier shuts off when the bucket is full, or
when the bucket is removed or not replaced in the
Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restart
operation in the first 3 minutes.This is to protect the
unit. Operation will automatically start after 3 minutes.
Auto-Restart
If the unit breaks off unexpectedly due to the power
cut, it will restart with the previous function setting
automatically when the power resumes.
Display(On some models)
Shows the set % humidity level from 35% to 85% or
auto start/stop time (0~24) while setting, then shows
the actual(±5% accuracy) room % humidity level in a
range of 30% RH(Relative Humidity) to 90%RH(Relative
Humidity).
Error Codes:
AS-Humidity sensor error;
ES-Temperature sensor error;
Eb-Bucket is removed or not in right position--Replace
the bucket in the right position.(On some models)
Protection Code:
P2-Bucket is full or bucket is not in right position--
Empty the bucket and replace it in the right
position.(only available for the uint with no pump
feature.)
P2-Bucket is full -- Empty the bucket.(only available for
the unit with pump feature.)
Note: When one of the above malfunctions occurs,
turn off the unit, and check for any obstructions.
Restart the unit, if the malfunction is still present, turn
off the unit and unplug the power cord. Contact the
manufacturer or its service agents or a similar qualified
person for service.