System Setup Requirements
•
When using the ASD as an integral part of a larger system, it is the responsibility of the ASD
installer or maintenance personnel to ensure that there is a fail-safe in place, i.e., an arrangement
designed to switch the system to a safe condition if there is a fault or failure.
•
System safety features should be employed and designed into the integrated system in a manner
such that system operation, even in the event of system failure, will not cause harm or result in
personnel injury or system damage (i.e., E-Off, Auto-Restart settings, System Interlocks, etc.).
•
The programming setup and system configuration of the ASD may allow it to start the motor
unexpectedly. A familiarity with the Auto-restart settings is a requirement to use this product.
•
Improperly designed or improperly installed system interlocks may render the motor unable to
start or stop on command.
•
The failure of external or ancillary components may cause intermittent system operation, i.e.; the
system may start the motor without warning.
•
There may be thermal or physical properties, or ancillary devices integrated into the overall
system that may allow for the ASD to start the motor without warning. Signs at the equipment
installation must be posted to this effect.
•
If a secondary magnetic contactor (MC) is used between the ASD and the load, it should be
interlocked to halt the ASD before the secondary contact opens. If the output contactor is used for
bypass operation, it must be interlocked such that commercial power is never applied to the ASD
output terminals (U, V, and W).
•
Power factor improvement capacitors or surge absorbers must not be installed on the output of
the ASD.
•
Use of the built-in system protective features is highly recommended (i.e., E-Off, Overload
Protection, etc.).
•
The operating controls and system status indicators should be clearly readable and positioned
where the operator can see them without obstruction.
•
Additional warnings and notifications shall be posted at the equipment installation location as
deemed required by
Qualified Personnel
.
Summary of Contents for T300MVi MEDIUM VOLTAGE
Page 18: ... xviii This page intentionally left blank ...
Page 85: ... 64 DRIVE INSTALLATION DRAWINGS cont d Frame G4P drive lifting and assembly ...
Page 86: ... 65 DRIVE INSTALLATION DRAWINGS cont d Frame G4P drive main cable installation ...
Page 87: ... 66 DRIVE INSTALLATION DRAWINGS cont d Frame G4P module lifting and installation D C B A ...
Page 89: ... 68 DRIVE INSTALLATION DRAWINGS cont d Frame H4P drive lifting and assembly ...
Page 90: ... 69 DRIVE INSTALLATION DRAWINGS cont d Frame H4P drive main cable installation ...
Page 91: ... 70 DRIVE INSTALLATION DRAWINGS cont d Frame H4P module lifting and installation ...