FILE NO. SVM-13092-2
Unit model
Indoor
RAS
-1
3
7
S
KV
-E
6
Outdoor
RAS
-1
3
7
S
AV
-E
6
Cooling capacity
(kW)
Cooling capacity range
(kW)
Heating capacity
(kW)
Heating capacity range
(kW)
Power supply
1Ph/50Hz/220-240V , 1Ph/60Hz/220-230V
Electric
Indoor
Operation mode
Co
o
ling
H
ea
ting
characteristic
Running current
(A)
0.21-0.19
0.24-0.22
Power consumption
(W)
35
40
Power factor
(%)
76
76
Outdoor
Operation mode
Cooling
Heating
Running current
(A)
5.16-4.72
4.46-4.08
Power consumption
(W)
1065
910
Power factor
(%)
94
93
Starting current
(A)
COP (Cooling / Heating)
2.86/3.79
Operating
Indoor
High
(Cooling / Heating)
(dB-A)
41/42
noise
Medium
(Cooling / Heating)
(dB-A)
35/36
Low
(Cooling / Heating)
(dB-A)
28/29
Outdoor
(Cooling / Heating)
(dB-A)
48/50
Indoor unit
Unit model
RAS
-1
3
7
S
KV
-E
6
Dimension
Height
(mm)
275
Width
(mm)
790
Depth
(mm)
205
Net weight
(kg)
9
Fan motor output
(W)
20
Air flow rate
(Cooling / Heating)
(m
3
/ min)
9.5/9.8
Outdoor unit
Unit model
RAS
-1
3
7
S
AV
-E
6
Dimension
Height
(mm)
530
Width
(mm)
660
Depth
(mm)
240
Net weight
(kg)
28
Compressor
Motor output
(W)
750
Type
Model
ASM89D16UEZ
Fan motor output
(W)
43
Air flow rate
(Cooling / Heating)
(m
3
/ min)
31/31
Piping
Type
Flare connection
connection
Indoor unit
Liquid side
(mm)
6.35
Gas side
(mm)
9.52
Outdoor unit
Liquid side
(mm)
6.35
Gas side
(mm)
9.52
Maximum length
(m)
15
Maximum charge-less length
(m)
15
Maximum height difference
(m)
8
Refrigerant
Name of refrigerant
R410A
Weight
(kg)
0.63
Wiring
Power supply
3 Wires: Includes earth (Outdoor)
connection
Interconnection
4 Wires: Includes earth
Usable temperature range
Indoor
(Cooling / Heating)
(
o
C)
21-32/0-28
Outdoor
(Cooling / Heating)
(
o
C)
-10-46/-15-24
* The specification may be subject to change without notice for purpose of improvement.
0.95-4.0
1.2-3.6
3.6
3.15
5.37
4.70
2-2. Specification
– 5 –
Twin rotary type with DC-inverter variable speed contro
l to Single
rotary type with DC-inverter variable speed control