DK40i Configuration
Expansion KSU
2-8
Strata DK I&M 6/00
Peripherals
An Expansion KSU can support PIOU, PIOUS, RSSU and PEPU PCBs (see
options).
PIOU or PIOUS
The PIOU/PIOUS provides one dedicated RS-232 port for Station Message Detail Recording
(SMDR) connection to a call accounting device and one of the following:
♦
a TTY/RS-232 port which can connect to a customer-provided VM SMDI or external modem
for remote maintenance, or to a local PC with DKAdmin
♦
connectors for an internal modem (IMDU) for remote maintenance and administration
RSSU
The RSSU provides one TTY/RS-232 port for a connection to a VM SMDI or customer-provided
external modem for remote maintenance, or to a local PC with DKAdmin. The RSSU does not
support SMDR or IMDU.
Any device that connects to the PIOU, PIOUS, or RSSU should not be considered a station and
does not affect the system’s station capacity.
1. Amplified page output (single zone, 3 watts, 8 ohms) on the PIOU and PEPU is not available on the DK40i
2. These functions are standard (built-in) to the DK40i Base KSU.
Table 2-6
DK40i Interface PCB Options
Interface Options
RSSU
PIOU
PIOUS
PEPU
TSIU
DK40i
Base
Zone page interface (unamplified, 4 zones)
X
Unamplified page output (single zone, 600 ohm,
duplex)
X
Night transfer or Music-on-hold control relay
X
X
X
X
Door lock or external amplifier control relay
X
X
X
X
IMDU disables TTY output when piggy-backed
onto PIOU or PIOUS cards
X
X
Remote Maintenance using customer-provided
external modem, StrataControl and/or DKAdmin
PC (requires TTY output port)
X
X
X
X
SMDR output (RS-232/6-wire modular connector)
X
X
X
Alarm sensor
X
X
Voice Mail SMDI (requires TTY output port)
X
X
X
X
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...