ELECTRICAL WORK
Wiring between units
1. Connect the wires between the units correctly.
Errors made in the connections can result in the unit malfunctioning.
2. Connect the control wires between the outdoor unit and indoor unit as shown in the figure below :
Connecting cable
Earth line
Cabling
1. Remove a screw and then remove cover of the electric parts box.
2. Strip wire ends (10 mm).
3. Match wire colors with terminal numbers on indoor and outdoor units’ terminal blocks and firmly screw wires to
the corresponding terminals.
4. Connect the ground wires to the corresponding terminals.
5. Fix the cable with cord clamp.
6. Fix cover of the parts box and the terminal block surely with the fixing screws.
Make a loop on the cable for margin of the length so that the electric parts box can be taken out during servicing.
Connecting cable
Air inlet grille
Front panel
Cord clamp
Terminal cover
Screw
Screw
Earth line
Wiring connections