(8) ECONO operation control
When the [ECO] button is pushed, ECONO
operation is performed by restraining air flow
and compressor motor speed. The set
temperature is changed also.
FILE NO. SVM-05019
1) The set temperature increased 0.5°C per hour up
to 2°C starting from the set temperature when
ECONO has been received.
2) Indoor air flow is controlled between L+ and UL.
The compressor motor speed in control as shown
in Fig. 6-2-5
together with the timer OFF function. Each
time of pressing [COMFORT SLEEP] button
the off timer setting changes in the sequence
of 1, 3, 5 or 9 hours.
(10) Hi POWER operation control.
When the [Hi POWER] button is pushed
Hi Power operation is performed by change
set temperature and air flow (display on the
remote control does not change).
Fig. 6-2-5
(9) COMFORT SLEET operation control.
When the [COMFORT SLEEP] button is
pushed, the ECONO operation activate
Fig. 6-2-6
1) Changing of set temperature.
−