Outdoor Unit

Installation Manual

 

WARNING

•  Do not use any refrigerant different from the one specified for complement or replacement.

Otherwise, abnormally high pressure may be generated in the refrigeration cycle, which 
may result in a failure or explosion of the product or an injury to your body. 

•  Installation work must be requested from the supplying retail dealership or professional 

vendors. Self-installation may cause water leakage, electrical shock, or fire as a result of 
improper installation. 

•  Specified tools and pipe parts for model R410A are required, and installation work must 

be done in accordance with the manual. HFC type refrigerant R410A has 1.6 times more 
pressure than that of conventional refrigerant (R22). Use the specified pipe parts, and 
ensure correct installation, otherwise damage and/or injury may be caused. At the same 
time, water leakage, electrical shock, and fire may occur. 

•  Be sure to install the unit in a place which can sufficiently bear its weight. If the load bearing 

of the unit is not enough, or installation of the unit is improper, the unit may fall and result in 
injury. 

•  Electrical work must be performed by a qualified electrical engineer in accordance with 

the code governing such installation work, internal wiring regulations, and the manual. A 
dedicated circuit and the rated voltage must be used. Insufficient power supply or improper 
installation may cause electrical shock or fire. 

•  Use a cabtyre cable to connect wires in the indoor/outdoor units. Midway connection, 

stranded wire, and single-wire connections are not allowed. Improper connection or fixing 
may cause a fire. 

•  Wiring between the indoor unit and outdoor units must be well shaped so that the cover can 

be firmly placed. Improper cover installation may cause increased heat, fire, or electrical 
shock at the terminal area. 

•  Be sure to use only approved accessories or the specified parts. Failure to do so may 

cause the unit to fall, water leakage, fire or electrical shock. 

•  After the installation work, ensure that there is no leakage of refrigerant gas. If the 

refrigerant gas leaks out of the pipe into the room and is heated by fire or something else 
from a fan heater, stove or gas range, it causes generation of poisonous gas. 

•  Make sure the equipment is properly earthed. Do not connect the earth wire to a gas pipe, 

water pipe, lightning conductor, or telephone earth wire. Improper earth work may be the 
cause of electrical shock. 

•  Do not install the unit where flammable gas may leak. If there is any gas leakage or 

accumulation around the unit, it can cause a fire. 

•  Do not select a location for installation where there may be excessive water or humidity, 

such as a bathroom. Deterioration of insulation may cause electrical shock or fire. 

•  Installation work must be performed following the instructions in this installation manual. 

Improper installation may cause water leakage, electrical shock or fire. Check the following 
items before operating the unit.
-  Be sure that the pipe connection is well placed and there are no leaks.
-  Check that the service valve is open. If the service valve is closed, it may cause 

overpressure and result in compressor damage. At the same time, if there is a leak in the 
connection part, it may cause air suction and overpressure, resulting in burst or injury. 

•  The following must be certainly done during pump down.

•  Do not incorporate air into the refrigeration cycle.
•  Close the 2 service valves. Stop the compressor and remove the refrigerant pipe.
If the refrigerant pipe is removed when the compressor is operating and service valves are 
opened, the refrigerant cycle will inhale unwanted matter such as air and the pressure in the 
cycle becomes abnormally elevated. It may cause a burst or injury. 

•  Do not modify the power cable, connect the cable midway, or use a multiple outlet 

extension cable. Doing so may cause contact failure, insulation failure, or excess current, 
resulting in fire or electrical shock. 

1116791101_EN.indd   4

1116791101_EN.indd   4

2/3/58 BE   2:20 PM

2/3/58 BE   2:20 PM

Summary of Contents for RAS-3M26S3AV-A

Page 1: ... TYPE Installation Manual Outdoor Unit Model name RAS 5M34S3AV A RAS 4M27S3AV A RAS 3M26S3AV A NOTE Descriptions about operations for the E unit in this manual are not applicable to RAS 4M27S3AV A Descriptions about operations for the D unit and the E unit in this manual are not applicable to RAS 3M26S3AV A 1116791101 1116791101_EN indd c1 1116791101_EN indd c1 2 3 58 BE 2 20 PM 2 3 58 BE 2 20 PM ...

Page 2: ...evice and Outdoor Unit 11 10 Test run 14 Please read this Installation Manual carefully before installing the Air Conditioner This Manual describes the installation method of the outdoor unit For installation of the indoor unit refer to the Installation Manual attached to the indoor unit IMPORTANT NOTICE For details on how to install the indoor units refer to the installation manual accompanying t...

Page 3: ...ING It indicates that incorrect use of this unit may cause severe injury or death CAUTION It indicates that incorrect use of this unit may cause personal injury 2 or property damage 3 1 A severe injury refers to blindness injury burns hot or cold electrical shock bone fracture or poisoning that leaves after effects and requires hospitalization or extended out patient treatment 2 Personal injury me...

Page 4: ...wiring Turn off main power supply before attempting any electrical work Make sure all power switches are off Failure to do so may cause electric shock Connect the connecting cables correctly If the connecting cables are connected wrongly electric parts may be damaged Check the earth wire that it is not broken or disconnected before installation Do not install near concentrations of combustible gas...

Page 5: ...do so may cause the unit to fall water leakage fire or electrical shock After the installation work ensure that there is no leakage of refrigerant gas If the refrigerant gas leaks out of the pipe into the room and is heated by fire or something else from a fan heater stove or gas range it causes generation of poisonous gas Make sure the equipment is properly earthed Do not connect the earth wire t...

Page 6: ... be connected to the main power supply by means of a circuit breaker depending on the place where the unit is installed Failure to do so may cause electrical shock Follow the instructions in this installation manual to arrange the drain pipe for proper drainage from the unit Ensure that drained water is discharged Improper drainage can result in water leakage causing water damage to furniture Tigh...

Page 7: ...ditioner differs depending on the combination of the indoor units which are operated The information in this specifications table applies for the combinations with the catalogue For operation read the owner s manual packed with the indoor unit Equipment complying with IEC 61000 3 12 1 If the air conditioner is used in conditions other than the above the safety protection functions may be activated...

Page 8: ...ioner under low outside temperature conditions Outside temp 5 C or lower In COOL mode prepare a duct or wind shield so that it is not affected by the wind Necessary Space for Installation If you need to install the outdoor unit in a location where there are some obstructions or a wall secure sufficient space as shown in the figure below The cooling heating effect may be reduced by 10 Upper side vi...

Page 9: ... core Setting Pin using the charge hose NOTE If a control valve or charge valve is attached to the charge hose leak of R410A refrigerant can be avoided 2 Open the Handle Low of the gauge manifold valve fully then operate the vacuum pump Loosen the flare nut of the at the gas end a little to make sure that air is taken in then tighten the nut If you find air is not taken in make sure that the charg...

Page 10: ...rming Additional Installation of an Indoor Unit 1 Collect refrigerant from the outdoor unit 2 Turn off the circuit breaker 3 Perform additional installation referring to the procedure from Refrigerant Piping Connection on the previous page Pump down Operation Recovering refrigerant CAUTION Since the forcible running for collecting refrigerant stops automatically after 10 minutes finish collecting ...

Page 11: ... terminal numbers on the terminal block of each unit Incorrect connection may cause a failure 1 Detach the front panel from the outdoor unit 2 Remove the cord clamp 3 Connect the wires for the power source and each indoor unit Connect the connecting cable to the terminal as identified by the matching numbers on the terminal block of the indoor and the outdoor unit 4 Fix the wiring connections for ...

Page 12: ... connecting wire is incorrect electric parts may be damaged Ensure that all terminals are securely fixed so preventing any external forces having a negative effect on the terminals Do not connect the DRED mains cable to the terminal block of the outdoor unit Power supply and Indoor Outdoor connecting Improper installation may result in fire Connect the demand connecting wires and relay connector R...

Page 13: ...02 CN100 CN105 Locally procured Power supply Indoor A E unit Connecting WARNING Do not connect the DRED mains cable to the terminal block of the outdoor unit Power supply and Indoor Outdoor connecting Improper installation may result in fire For the power supply of the DRED prepare exclusive power supply separated from that of the outdoor unit WARNING Connect the wire 4 wire with a round terminal ...

Page 14: ...he demand response event i e cooling or heating Wiring procedure 1 Securely fasten the demand connecting wires with the cord clamp located at the upper portion of the terminal block so that no external force is applied to the terminal The demand connecting wires having a relay connector RJ45 should be wired in such a manner as to prevent water intrusion into the relay connector 2 Bundle the demand...

Page 15: ...in units B C and E Trouble in units B D and E Trouble in units C D and E Trouble in units A B C and D Trouble in units A B C and E Trouble in units A B D and E Trouble in units A C D and E Trouble in units B C D and E Trouble in all units Service valve stays closed Gas Leak Inspection Refer to the Gas Leak Inspection on page 9 Test run 1 If you perform the test run in summer start running in the c...

Page 16: ...Moo 5 Bangkadi Industrial Park Tivanon Road Tambol Bangkadi Amphur Muang Pathumthani 12000 Thailand 1116791001_EN indd 15 01 22 15 10 52 AM 1116791101_EN indd 15 1116791101_EN indd 15 2 3 58 BE 2 20 PM 2 3 58 BE 2 20 PM ...

Reviews: