ELECTRICAL WORKS
ELECTRICAL WORKS
The power supply can be selected to connect to indoor unit or outdoor unit. Choose proper way and connect the power supply and connecting cable by follow
the instruction as following.
Indoor unit
Outdoor unit
Valve cover
Terminals block
How to install the air inlet grille on the indoor
unit
• When attaching the air inlet grille, the contrary of the removed operation is
performed.
Wiring of the connecting cable can be carried out without removing the
front panel.
1. Remove the air inlet grille.
Open the air inlet grille upward and pull it toward you.
2. Remove the terminal cover and cord clamp.
3. Insert the connecting cable (according to the local cords) into the pipe hole
on the wall.
4. Take out the connecting cable through the cable slot on the rear panel so
that it protrudes about 20 cm from the front.
5. Insert the connecting cable fully into the terminal block and secure it tightly
with screws.
6. Tightening torque : 1.2 N·m (0.12 kgf·m)
7. Secure the connecting cable with the cord clamp.
8. Fix the terminal cover, rear plate bushing and air inlet grille on the indoor
unit.
Cord clamp
Terminal cover
Screw
Screws
Air inlet grille
Front panel
1. Remove the valve cover, the electric parts cover and the cord clamp from
the outdoor unit.
2. Connect the connecting cable to the terminal as identi
fi
ed by the
matching numbers on the terminal block of indoor and outdoor unit.
3. Insert the power cord and the connecting cable carefully into the terminal
block and secure it tightly with screws.
4. Use vinyl tape, etc. to insulate the cords which are not going to be used.
Locate them so that they do not touch any electrical or metal parts.
5. Secure the power cord and the connecting cable with the cord clamp.
6. Attach the electric parts cover and the valve cover on the outdoor unit.
Model
RAS-18J2KVSG-E
RAS-B22J2KVSG-E
RAS-B24J2KVSG-E
Power source
50Hz, 220 – 240 V Single phase
Maximum running current
9.50 A
10.50 A
12.50 A
Circuit breaker rating
15 A
15 A
15 A
Power supply cable
H07RN-F or 60245 IEC66 (2.5 mm
2
or more)
Connecting cable
H07RN-F or 60245 IEC66 (2.5 mm
2
or more)
Wiring Connection
Summary of Contents for RAS-18J2AVSG-E
Page 20: ......
Page 40: ......
Page 60: ......
Page 80: ......
Page 100: ......
Page 120: ......
Page 140: ......
Page 160: ......
Page 199: ......
Page 219: ......
Page 239: ...18 ...
Page 259: ......
Page 298: ...18 ...
Page 318: ......
Page 338: ......
Page 358: ......
Page 378: ......
Page 398: ......
Page 418: ......
Page 438: ......
Page 458: ......
Page 478: ......