Piping and Drain Hose Installation

*  Since dewing results in a machine trouble, make sure to insulate both con-

necting pipes. (Use polyethylene foam as insulating material.)

     

Piping and drain hose forming

1.  Die-cutting front panel slit

 

Cut out the slit on the leftward or right side of the front panel for the left or 
right connection and the slit on the bottom left or right side of the front panel 
for the bottom left or right connection with a pair of nippers.

2.  Changing drain hose

 

For  leftward  connection,  bottom-leftward  connection  and  rearleftward 
connection’s  piping,  it  is  necessary  to  change  the  drain  hose  and  drain 
cap.

How to remove the drain cap

Clip the drain cap by needle-
nose pliers and pull out.

Heat insulator

Drain hose

How to remove the drain hose

•  The drain hose can be removed by removing the 

screw securing the drain hose and then pulling out 
the drain hose.

•  When removing the drain hose, be careful of any 

sharp edges of steel plate. The edges can injuries.

•  To install the drain hose, insert the drain hose 

Þ

 rmly until the connection part contacts with heat 

insulator, and the secure it with original screw.

How to 

Þ

 x the drain cap

1)  Insert hexagon 
 

wrench (4 mm) 

 

in a center head.

4 mm

2)  Firmly insert the drain cap.

Do not apply lubricating oil
(refrigerant machine oil) when
inserting the drain cap. Application
causes deterioration and drain
leakage of the plug.

Insert a hexagon
wrench (4 mm).

No gap

Firmly insert the drain hose and drain cap; otherwise, water may leak.

In case of right or left piping

•  After scribing slits of the front panel with a 

knife  or  a  making-off  pin,  cut  them  with  a 
pair of nippers or an equivalent tool.

 

In case of bottom right or bottom left piping

•  After scribing slits of the front panel with a 

knife or a making-off pin, cut them with a 
pair of nippers or an equivalent tool.

 

Slit

Slit

Left-hand connection with piping

•  Bend the connecting pipe so that it is laid within 43 mm above the wall sur-

face. If the connecting pipe is laid exceeding 43 mm above the wall surface, 
the indoor unit may unstably be set on the wall.

  When bending the connecting pipe, make sure to use a spring bender so as 

not to crush the pipe.

Bend the connecting pipe within a radius of 30 mm.

To connect the pipe after installation of the unit (

Þ

 gure)

10(7)SKV

10SKVR

13(7)~16(7)SKV(R)

A

270

270

B

170

230

How to install the air inlet grille on the indoor 
unit

•  When attaching the air inlet grille, 

the contrary of the removed 
operation is performed.  

Wiring Connection

Wiring of the connecting cable can be carried out without removing the 
front panel.

1.  Remove the air inlet grille.
 

Open the air inlet grille upward and pull it toward you.

2.  Remove the terminal cover and cord clamp.
3.  Insert the connecting cable (according to the local cords) into the pipe hole 

on the wall.

4.  Take out the connecting cable through the cable slot on the rear panel so 

that it protrudes about 15 cm from the front.

5.  Insert the connecting cable fully into the terminal block and secure it tightly 

with screws.

6.  Tightening torque : 1.2 N·m (0.12 kgf·m)
7.  Secure the connecting cable with the cord clamp.
8.  Fix the terminal cover, rear plate bushing and air inlet grille on the indoor 

unit.

     

How to connect the connecting cable

•  Be sure to refer to the wiring system diagram labeled inside the front 

panel.

•  Check local electrical cords and also any speci

Þ

 c wiring instructions or 

limitations. 

 

NOTE

•  Use stranded wire only.
•  Wire type : H07RN-F or more

CAUTION

CAUTION

1

2

3

1

3

2

10 mm

10 mm

50 mm 

110 mm

Cord clamp

Terminal block

Terminal cover

Screw

Earth line

Screw

Connecting cable

Screw

Earth line

Connecting cable

Stripping length of the connecting cable

abou

t 15 c

m

80

A mm

B mm

m

3

4

Liquid side

Gas side

(To the forefront of 

ß

 are)

Outward form of indoor unit

R 30 mm (Use polisin (polyethylene)
core or the like for bending pipe.)

Use the handle of screwdriver, etc.

1110251155-EN.indd   4

12/18/07   3:47:24 PM

Summary of Contents for RAS-16 SKV Series

Page 1: ...ies AIR CONDITIONER SPLIT TYPE INSTALLATION MANUAL ENGLISH ESPAÑOL FRANÇAIS ITALIANO DEUTSCH PORTUGUÊS POLSKI ESKY PУCСКИЙ HRVATSKI MAGYAR TÜRKÇE NEDERLANDS ΕΛΛΗΝΙΚΑ SVENSKA SUOMI NORSK DANSK ROMÂN БЪЛГАРСКИ EESTI LATVISKI SLOVEN INA SLOVENŠ INA Cover indd 8 08 3 55 55 PM ...

Page 2: ...de Gás 7 DeÞnição do interruptor do telecomando 7 Selecção A B do telecomando 7 Execução do Teste 7 DeÞnindo de Reiniciação Automática 7 PT SPIS TRE CI ZASADY BEZPIECZE STWA SCHEMAT INSTALACYJNY URZ DZENIA WEWN TRZNEGO I ZEWN TRZNEGO 2 Dodatkowe Cz ci Instalacyjne 2 URZ DZENIE WEWN TRZNE 3 Miejsce Instalacji 3 Wycinanie Otworu oraz Monta P yty Instalacyjnej 3 Prace Elektryczne 3 Pod czenie Okablow...

Page 3: ...cul de instalare 3 Executarea unei g6uri 4i montarea pl6cii de instalare 3 Lucr6rile electrice 3 Racordarea cablurilor 4 Instalarea 5evilor 4i a furtunului de evacuare 4 Fixarea unit65ii interioare 5 Evacuarea 5 UNITATEA EXTERIOAR 5 Locul de instalare 5 Racordarea 5evilor de lichid refrigerent 6 Evacuarea 6 Racordarea cablurilor 6 ALTELE 7 VeriÞ carea scurgerilor de gaz 7 Setarea butonului selecto...

Page 4: ...ensure that water or dust does not enter Moreover do not use any existing piping as its pressure withstand may be insufÞcient and may contain impurities FOR USE BY QUALIFIED PERSONS ONLY TURN OFF MAIN POWER SUPPLY BEFORE ATTEMPTING ANY ELECTRICAL WORK MAKE SURE ALL POWER SWITCHES ARE OFF FAILURE TO DO SO MAY CAUSE ELECTRIC SHOCK CONNECT THE CONNECTING CABLE CORRECTLY IF THE CONNECTING CABLE IS CON...

Page 5: ...peration For the rear left and left piping Wall Make sure to run the drain hose sloped downward Do not allow the drain hose to get slack Cut the piping hole sloped slightly The auxiliary piping can be connected to the left rear left rear right right bottom right or bottom left Right Rear right Bottom right Rear left Bottom left Left 6 mm thick heat resisting polyethylene foam 1 Batteries Pan head ...

Page 6: ...nd outlet A place which allows easy installation of the piping to the outdoor unit A place which allows the front panel to be opened The indoor unit shall be installed as top of the indoor unit comes to at least 2 m height Also it must be avoided to put anything on the top of the indoor unit CAUTION 5 4 45 5 7 Side view Top view Indoor unit R e c e p t i o n r a n g e Remote control Remote control...

Page 7: ...ont panel with a knife or a making off pin cut them with a pair of nippers or an equivalent tool Slit Slit Left hand connection with piping Bend the connecting pipe so that it is laid within 43 mm above the wall sur face If the connecting pipe is laid exceeding 43 mm above the wall surface the indoor unit may unstably be set on the wall When bending the connecting pipe make sure to use a spring be...

Page 8: ...oor side 50 mm or more Do not put the drain hose end into water Do not put the drain hose end in the drainage ditch Do not form the drain hose into a wavy shape Do not rise the drain hose Extension drain hose Inside the room Drain hose Shield pipe Arrange the drain pipe for proper drainage from the unit Improper drainage can result in dew dropping Wall Drain guide Space for pipes This air conditio...

Page 9: ...of the vacuum pump enters the air conditioner which use R410A refrigeration cycle trouble may result 1 Connect the charge hose from the manifold valve to the service port of the packed valve at gas side 2 Connect the charge hose to the port of the vacuum pump 3 Open fully the low pressure side handle of the gauge manifold valve 4 Operate the vacuum pump to start evacuating Perform evacuating for a...

Page 10: ... leak with a gas leak detector or soap water This product is designed so that after a power failure it can restart automatically in the same operating mode as before the power failure Press and hold the RESET button for about 3 seconds After 3 seconds the electronic beeper makes three short beeps to tell you the Auto Restart has been selected To cancel the Auto Restart follow the steps described i...

Reviews: