5

 

NOTE

If the pipe is bent incorrectly, the indoor unit may unstably be set on the wall.
After  passing  the  connecting  pipe  through  the  pipe  hole,  connect  the 
connecting  pipes  to  the  auxiliary  pipes  and  wrap  the  facing  tape  around 
them.

•  Bind  the  auxiliary  pipes  (two)  and  connecting  cable  with  facing  tape 

tightly.  In  case  of  leftward  piping  and  rear-leftward  piping,  bind  the 
auxiliary pipes (two) only with facing tape.

Auxiliary pipes

Indoor unit

Connecting cable

Installation plate

 

•  Carefully arrange pipes so that any pipe does not stick out of the rear 

plate of the indoor unit.

•  Carefully connect the auxiliary pipes and connecting pipes to one an-

other and cut off the insulating tape wound on the connecting pipe to 
avoid double-taping at the joint; moreover, seal the joint with the vinyl 
tape, etc.

•  Since dewing results in a machine trouble, make sure to insulate both 

connecting pipes. (Use polyethylene foam as insulating material.)

•  When bending a pipe, carefully do it, not to crush it. 

CAUTION

Indoor Unit Fixing

•  For  detaching  the  indoor  unit  from  the 

installation plate, pull the indoor unit toward 
you  while  pushing  its  bottom  up  at  the 
speci

Þ

 ed parts.

Push

Push

Press

(unhook)

Hook

Hook here.

1

2

 Installation plate

1

1.  Pass the pipe through the hole in the wall and hook the indoor unit on the 

installation plate at the upper hook.

2.  Swing the indoor unit to right and left to con

Þ

 rm that it is 

Þ

 rmly hooked up on 

the installation plate.

3.  While pressing the indoor unit onto the wall, hook it at the lower part on the 

installation plate. Pull the indoor unit toward you to con

Þ

 rm that it is 

Þ

 rmly 

hooked up on the installation plate.

Drainage

1.  Run the drain hose sloped downwards.

2.  Put water in the drain pan and make sure that the water is drained out of 

doors.

3.  When  connecting  extension  drain  hose,  insulate  the  connecting  part  of 

extension drain hose with shield pipe.

 

NOTE

•  The hole should be made at a slight downward slant on the outdoor side.

50 mm
or more

Do not put the
drain hose end
into water.

Do not put the
drain hose end
in the drainage ditch.

Do not form the
drain hose into
a wavy shape.

Do not rise the
drain hose.

Extension drain hose

Inside the room

Drain hose

Shield pipe

Arrange the drain pipe for proper drainage from the unit.
Improper drainage can result in dew-dropping.

Wall

Drain
guide

Space for pipes

This air conditioner has the structure designed 
to drain water collected from dew, which forms 
on the back of the indoor unit, to the drain pan. 
Therefore, do not store the power cord and other 
parts at a height above the drain guide.

CAUTION

OUTDOOR UNIT

Installation Place

•  A place which provides the spaces around the outdoor unit as shown in the 

diagram

•  A place which can bear the weight of the outdoor unit and does not allow an 

increase in noise level and vibration

•  A  place  where  the  operation  noise  and  discharged  air  do  not  disturb  your 

neighbors

•  A place which is not exposed to a strong wind
•  A place free of a leakage of combustible gases
•  A place which does not block a passage
•  When the outdoor unit is to be installed in an elevated position, be sure to 

secure its feet.

•  An allowable length of the connecting pipe is up to 10 m for 10(7)SAV Series 

and 20 m for 13(7)~16(7)SAV Series.

•  An  allowable  height  level  is  up  to  8  m  for  10(7)SAV  Series  and  10  m  for 

13(7)~16(7)SAV Series.

•  A place where the drain water does not raise any problems

CAUTION

1.  Install the outdoor unit without anything blocking the air discharging.
2.  When the outdoor unit is installed in a place always exposed to strong 

wind like a coast or on a high storey of a building, secure the normal fan 
operation using a duct or a windshield.

3.  In particularly windy areas, install the unit such as to avoid admission of 

wind.

4.  Installation in the following places may result in trouble.
 

Do not install the unit in such places.

 

•  A place full of machine oil

 

•  A saline-place such as the coast

 

•  A place full of sul

Þ

 de gas

 

•  A place where high- 

 

  frequency waves are likely to 

be generated as from audio 
equipment, welders, and medical equipment

Strong
         wind

1110251155-EN.indd   5

12/18/07   3:47:26 PM

Summary of Contents for RAS-16 SKV Series

Page 1: ...ies AIR CONDITIONER SPLIT TYPE INSTALLATION MANUAL ENGLISH ESPAÑOL FRANÇAIS ITALIANO DEUTSCH PORTUGUÊS POLSKI ESKY PУCСКИЙ HRVATSKI MAGYAR TÜRKÇE NEDERLANDS ΕΛΛΗΝΙΚΑ SVENSKA SUOMI NORSK DANSK ROMÂN БЪЛГАРСКИ EESTI LATVISKI SLOVEN INA SLOVENŠ INA Cover indd 8 08 3 55 55 PM ...

Page 2: ...de Gás 7 DeÞnição do interruptor do telecomando 7 Selecção A B do telecomando 7 Execução do Teste 7 DeÞnindo de Reiniciação Automática 7 PT SPIS TRE CI ZASADY BEZPIECZE STWA SCHEMAT INSTALACYJNY URZ DZENIA WEWN TRZNEGO I ZEWN TRZNEGO 2 Dodatkowe Cz ci Instalacyjne 2 URZ DZENIE WEWN TRZNE 3 Miejsce Instalacji 3 Wycinanie Otworu oraz Monta P yty Instalacyjnej 3 Prace Elektryczne 3 Pod czenie Okablow...

Page 3: ...cul de instalare 3 Executarea unei g6uri 4i montarea pl6cii de instalare 3 Lucr6rile electrice 3 Racordarea cablurilor 4 Instalarea 5evilor 4i a furtunului de evacuare 4 Fixarea unit65ii interioare 5 Evacuarea 5 UNITATEA EXTERIOAR 5 Locul de instalare 5 Racordarea 5evilor de lichid refrigerent 6 Evacuarea 6 Racordarea cablurilor 6 ALTELE 7 VeriÞ carea scurgerilor de gaz 7 Setarea butonului selecto...

Page 4: ...ensure that water or dust does not enter Moreover do not use any existing piping as its pressure withstand may be insufÞcient and may contain impurities FOR USE BY QUALIFIED PERSONS ONLY TURN OFF MAIN POWER SUPPLY BEFORE ATTEMPTING ANY ELECTRICAL WORK MAKE SURE ALL POWER SWITCHES ARE OFF FAILURE TO DO SO MAY CAUSE ELECTRIC SHOCK CONNECT THE CONNECTING CABLE CORRECTLY IF THE CONNECTING CABLE IS CON...

Page 5: ...peration For the rear left and left piping Wall Make sure to run the drain hose sloped downward Do not allow the drain hose to get slack Cut the piping hole sloped slightly The auxiliary piping can be connected to the left rear left rear right right bottom right or bottom left Right Rear right Bottom right Rear left Bottom left Left 6 mm thick heat resisting polyethylene foam 1 Batteries Pan head ...

Page 6: ...nd outlet A place which allows easy installation of the piping to the outdoor unit A place which allows the front panel to be opened The indoor unit shall be installed as top of the indoor unit comes to at least 2 m height Also it must be avoided to put anything on the top of the indoor unit CAUTION 5 4 45 5 7 Side view Top view Indoor unit R e c e p t i o n r a n g e Remote control Remote control...

Page 7: ...ont panel with a knife or a making off pin cut them with a pair of nippers or an equivalent tool Slit Slit Left hand connection with piping Bend the connecting pipe so that it is laid within 43 mm above the wall sur face If the connecting pipe is laid exceeding 43 mm above the wall surface the indoor unit may unstably be set on the wall When bending the connecting pipe make sure to use a spring be...

Page 8: ...oor side 50 mm or more Do not put the drain hose end into water Do not put the drain hose end in the drainage ditch Do not form the drain hose into a wavy shape Do not rise the drain hose Extension drain hose Inside the room Drain hose Shield pipe Arrange the drain pipe for proper drainage from the unit Improper drainage can result in dew dropping Wall Drain guide Space for pipes This air conditio...

Page 9: ...of the vacuum pump enters the air conditioner which use R410A refrigeration cycle trouble may result 1 Connect the charge hose from the manifold valve to the service port of the packed valve at gas side 2 Connect the charge hose to the port of the vacuum pump 3 Open fully the low pressure side handle of the gauge manifold valve 4 Operate the vacuum pump to start evacuating Perform evacuating for a...

Page 10: ... leak with a gas leak detector or soap water This product is designed so that after a power failure it can restart automatically in the same operating mode as before the power failure Press and hold the RESET button for about 3 seconds After 3 seconds the electronic beeper makes three short beeps to tell you the Auto Restart has been selected To cancel the Auto Restart follow the steps described i...

Reviews: