– 3
2
–
Item
2. Indoor fan
motor control
Operation flow and applicable data, etc.
<In cooling operation>
(This operation controls the fan speed at indoor unit side.)
The indoor fan (cross flow fan) is operated by the phase-
control induction motor. The fan rotates in 5 stages in
MANUAL mode, and in 5 stages in AUTO mode, respec-
tively. (Table 1)
Description
* Symbols
UH
: Ultra High
H
: High
M+
:
M
: Medium
L+
: Low+
L
: Low
L-
: Low–
UL
: Ultra Low
SUL
: Super Ultra Low
* The values of fan speed and air flow
volume
indicate
on the table are measured
when the louver is inclined downward.
Fan speed and air flow volume broadly
vary with position of louver.
1) When setting the fan speed to L,
L+, M, M+ or H on the remote
controller, the operation is
performed with the constant
speed shown in Fig. 1.
2) When setting the fan speed to
AUTO on the remote controller,
revolution of the fan motor is
controlled to the fan speed level
shown in Fig. 2 and Table 1
according to the setup tempera-
ture and room temperature.
(Fig. 1)
(Fig. 2)
(Table 1) Indoor fan air flow rate
+4.5 (+2.5)
Ta
°F [°C]
+3.5 (+2.0)
+2.7 (+1.5)
+2.0 (+1.0)
+1.0 (+0.5)
Tsc
a
b
c
d
e
M+(WB)
*3
*4
*5
L(W6)
Air volume AUTO
L
L+
M
M+
H
W6
(L + M) / 2
W9
(M + H) / 2
WC
Indication
Fan speed
Fan speed setup
COOL ON
AUTO
MANUAL
*3 : Fan speed =
[
(M+
)
–L
]
x 3/4 + L
*4 : Fan speed =
[
(M+
)
–L
]
x 2/4 + L
*5 : Fan speed =
[
(M+
)
–L
]
x 1/4 + L
(Linear approximation
from M+ and L)
FILE NO. SVM-13069
Fan speed
Air flow rate
Fan speed
Air flow rate
(rpm)
cfm (m3/h)
(rpm)
cfm (m3/h)
WF
UH
1210
336 (571)
1510
433 (735)
WE
H
1210
336 (571)
1510
433 (735)
WD
UH
M+
UH
1170
321 (546)
1480
422 (717)
WC
H
H
1120
303 (515)
1430
404 (686)
WB M+
M+ 1040 274 (465) 1280 350 (594)
WA
M
1000
248 (421)
1220
328 (557)
W9
M
L+
960
235 (400)
1150
302 (514)
W8
L
870
200 (340)
1000
248 (421)
W7
L+
L-
L+
850
194 (330)
980
241 (409)
W6
L
L
760
159 (270)
920
219 (372)
W5
L-
UL
L-
760
159 (270)
900
212 (360)
W4
UL
UL
700
141 (240)
840
190 (323)
W3
SUL
SUL
650
118 (200)
770
165 (280)
W2
SUL
500
65 (110)
620
110 (187)
W1
500
65 (110)
520
74 (126)
RAS-12
E
KV-UL
Fan speed
level
DRY
HEAT
COOL
RAS-09
E
KV-UL