-
32
-
7-2. Description of Operation Circuit
(1) When turning on the breaker, the operation lamp
blinks. This means that the power supply is on.
(2) When pressing [ ] button on the remote control,
receiving beep sounds from the indoor unit, and
the next operation is performed together with
opening the vertical air flow louver.
(3) Once the operation mode is set, it is memorized in
the microcontroller so that the previous operation
can be effected thereafter simply by pressing
[ ] button.
7-2-1. Fan only operation
([MODE] button on the remote control is set
to the fan only operation.)
(1) When [FAN] button is set to AUTO, the indoor fan
motor operates as shown in Fig. 7-2-1. When
[FAN] button is set to LOW, LOW
+
, MED, MED
+
or
HIGH, the motor operates with a constant air flow.
NOTE :
*1: The values marked with *1 are calculated and
controlled by the difference in motor speed
between M+ and L
-
.
Fig. 7-2-1 Setting of air flow [FAN:AUTO]
(2) The Hi POWER, ECO and COMFORT SLEEP
7-2-2. Cooling operation
([MODE] button on the remote control is set
to the cooling operation.)
(1) The compressor, 4-way valve, outdoor fan and
operation display on the remote control are
controlled as shown in Fig. 7-2-2.
Fig. 7-2-2
(2) When [FAN] button is set to AUTO, the indoor fan
motor operates as shown in Fig. 7-2-3. When
[FAN] button is set to LOW, LOW
+
, MED, MED
+
or
HIGH, the motor operates with a constant air flow.
NOTE :
*1: The values marked with *1 are calculated and
controlled by the difference in motor speed
between M+ and L
-
.
Fig. 7-2-3 Setting of air flow [FAN:AUTO]
*1
*1
*1
L
+3
°C
+2.5
+2
+1.5
+1
+0.5
-0.5
0
M+
(Room temp.)
−
(Preset temp.)
Preset
temp.
+2
+2.5
+3
°C
+1.5
+1
+0.5
0
M+
*1
*1
*1
L
(Room temp.)
(Preset temp.)
Preset
(Preset temp.: 22 °C)
temp.
0.5
°C
0
Preset
temp.
ON
ON
OFF OFF OFF ON
Compressor
4-way valve
Outdoor fan
OPERATION
display
(Room temp.)
(Preset temp.)
-
-
-
-
FILE NO. SVM-05001
operation cannot be set.