4
-
MODEL RAS-10UKHP-E4 / RAS-10UAH-E4 RAS-10UKP-E4 / RAS-10UA-E4
ITEM Cooling Heating Cooling
Capacity
220 V
240 V
220 V
240 V
220 V
240 V
kW 2.
65
2.7
0
2.95
3.
00
2.65 2.70
Phase
1
Æ
Power source
V
220
-
240
Hz
50
Power consumption kW
0.93
0.98
0.84
0.86
0.80 0.85
Power factor
%
95
92
94
91
97
95
Running
Indoor
A
0.15
current Outdoor A 4.
30
4.
27
3.90
3.77
3.60 3.58
Starting current
A
19
16
Moisture removal
lit/h
1.2
Noise
Indoor (H/M/L)
dB
39/33/26
Outdoor (220
-
240 V) dB
47
49
47
49
44
45
Refrigerant
Name of refrigerant
R22
Rated amount kg 0.76 0.6
8
Refrigerant control
Capillary tube
Gas side size
mm
Æ
9.52
Connection type
Flare connection
Liquid side size
mm
Æ
6.35
Interconnection Connection type
Flare connection
pipe
Maximum length
m
10*
1
(One way)
Maximum height
difference
INDOOR UNIT RAS-10UKHP-E4 RAS-10UKP-E4
Height
mm
275
Dimensions
Width
mm
790
Depth
mm
208
Net weight
kg
10
Evaporator type
Finned tube
Indoor fan type
Cross flow fan
High fan
m
3
/h
570
610
610
Air volume
Medium fan
m
3
/h
460
520
460
Low fan
m
3
/h
340
400
340
Fan motor output
W
20
Air filter
Honeycomb woven filter with PP frame
OUTDOOR UNIT RAS-10UAH-E4 RAS-10UA-E4
Height
mm
550
Dimensions
Width
mm
780
Depth
mm
270
Net weight kg 3
2
3
1
Condenser type
Finned tube
Outdoor fan type
Propeller fan
Airflow volume
m
3
/h
1740
1850
1740
1850
1740
1850
Fan motor output
W
20
Compressor
Mode
l
PH180X1C-4DZDN3 RM5510GNE94
Output
W
750
Safety device
Fuse, Overload relay
Louver type
Automatic louver
Usable outdoor temperature range
°C
15 ~ 43
-
10 ~ 24
15 ~ 43
m
5
FILE NO. SVM-05001