56
−
8-7. Others
8-7-1. Gas leak test
Fig. 8-7-1
•
Check the flare nut connections, valve stem cap
connections and service port cap connections for
gas leak with a leak detector or soap water.
8-7-2. Test operation
To switch the TEST RUN (COOL) mode, press
TEMPORARY button for 10 sec.
(The beeper will make a short beep.)
Fig. 8-7-2
8-7-3. Auto restart setting
This product is designed so that, after a power failure,
it can restart automatically in the same operating mode
as before the power failure.
Information
The product was shipped with Auto Restart function
in the off position. Turn it on as required.
<How to set the auto restart>
•
Press and hold the TEMPORARY button for about
3 seconds. After 3 seconds, the electronic beeper
makes three short beeps to tell you the Auto
Restart has been selected.
•
To cancel the Auto Restart, follow the steps
described in the section Auto Restart Function of
the Owner’s Manual.
Valve stem cap
connection
Service cap
connection
Valve cover
2.
Set the remote control selector switch with the
remote control
[B] is indicated on the liquid crystal display when
setting remote control selector switch to B. [A] is
not indicated on the display even if the selector
switch is set to A.
1)
Load the remote control with the batteries.
2)
Press the [CHK] button using something with
sharp point. (The preset temperature on the remote
control changes to [00].)
3)
Press the [MODE] button while pressing the
[CHK] button, [B] is indicted at the right of the
present temperature display.
•
To reset the switch to the [A] setting, press the
[MODE] button again while pressing the [CHK]
button.
Fig. 8-6-2
3.
Confirm that the indoor unit can operate with
the new setting.
TEMPORARY button
FILE NO. SVM-05001
[CHK]
button
[MODE]
button