EN
4
Toshiba 1108651075 (EN)
Wiring Connection
How to connect the power cord
For the air conditioner that does not have power cord,
connect a power cord to it as mentioned below.
(1) Open the air inlet grille upward.
(2) Remove the two screws securing the front panel.
(3) Before slightly open the lower part of the front panel, pushing at
specified bottom up until front take off from installation plate.
And then pull the upper part of the front panel toward you to
remove it from the rear plate.
(4) After removing the front panel, remove the power cord connect
cover and the cord clamp.
(5) Connect and secure the power supply cord and secure the cord
clamp and the power cord connect cover.
(6) Put the power supply cord through the notch.
(7) Be sure to smooth the notch with a file, etc.
Earth line
NOTE
•
Use stranded wire only.
•
Wire type : H07RN-F or more
Stripping length of the power supply cord
N
L
40 mm
10 mm
30 mm
10 mm
Electrical Work
1. The supply voltage must be the same as the rated voltage of the
air conditioner.
2. Prepare the power source for exclusive use with the air
conditioner.
CAUTION
•
This appliance can be connected to the mains in either of the
following two ways.
(1) Connection to fixed wiring:
A switch or circuit breaker which disconnects all poles and
has a contact separation of at least 3 mm must be
incorporated in the fixed wiring. An approved circuit breaker
or switches must be used.
(2) Connection with power supply plug:
Attach power supply plug with power cord and plug it into
wall outlet. An approved power supply cord and plug must
be used.
Model
07 Series
10 Series
Power source
50Hz, 220 – 240 V Single phase
Maximum running current
5A
7.5A
Plug socket & fuse rating
16A
Power cord
1 mm
2
or more
NOTE
•
Ensure all wiring is used within its electrical rating.
CAUTION
For the air conditioner with the power supply cord
•
If the power supply cord is damaged, it must be replaced by
the manufacturer, the service agency, or another similarly
qualified person in order to avoid hazard.
Power supply cord
Power cord connect cover
Earth line
Terminal block
Cord clamp
Screw
Screw
Screw
Push
Push
3
3
1
3
2
Air inlet grille
Front panel
Taking out the power cord
•
Put the power supply cord through the notch.
Notch