Toshiba 1108651075 (EN)
Shield pipe
Air filter
Hook
Hook
(Attac
h to the fr
ont panel.)
47 mm or more
120 mm or more
1
Installation plate
120 mm or more
2
Wireless remote control
5
Filter
6
Filter
3
Batteries
4
Remote control holder
8
Pan head
wood screw
Remark :
•
Detail of accessory and
installation parts can see in
the accessory sheet.
100 mm or more
45 mm or more
400 mm or more
Saddle
Vinyl tape
Apply after carrying
out a drainage test.
600 mm or more
Extension drain hose
(Not available, provided
by installer)
600 mm or more
INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS
Insulate the refrigerant pipes
separately with insulation, not
together.
6 mm thick heat resisting
polyethylene foam
Wall
Do not allow the drain hose to
get slack.
Make sure to run the drain
hose sloped downward.
Cut the piping
hole sloped
slightly.
For the rear left and left piping
Insert the cushion between
the indoor unit and wall, and
tilt the indoor unit for better
operation.
600 mm
90 mm
125 mm
108 mm
32.5 mm
86 mm
102 mm
320 mm
7 mm
30
•
Secure the outdoor unit with fixing bolts and nuts if the unit is likely to be
exposed to a strong wind.
•
Use
∅
8 mm or
∅
10 mm anchor bolts and nuts.
•
If it is necessary to drain the defrost water, attach drain nipple
9
and cap
water proof
!
to the bottom plate of the outdoor unit before installing it.
Fixing bolt arrangement of outdoor unit
Optional Installation
Parts
Parts name
Refrigerant piping
Liquid side
:
∅
6.35 mm
Gas side
:
∅
9.52 mm
Pipe insulating material
(polyethylene foam, 6 mm thick)
Putty, PVC tapes
Q’ty
One
each
1
One
each
Part
code
A
B
C
07 Series
Air outlet
Air inlet
Drain outlet
10 Series
500 mm
97 mm
53 mm
280 mm
Drain outlet
Air outlet
Air inlet
The auxiliary piping can be
connected to the left, rear left,
rear right, bottom right or
bottom left.
Rear
left
Left
Bottom left
Rear
right
Bottom right