Power supply cord of parts of appliance for outdoor use shall be at least polychloroprene sheathed flexible cord (design H07RN-F) or
cord designation 245 IEC66. (Shall be installed in accordance with national wiring regulations.)

CAUTION

This appliance must be connected to the main power supply by means of a circuit breaker or a switch with a contact separation of at
least 3 mm in all poles. If this is not possible, a power supply plug with earth must be used. This plug must be easily accessible after
installation. The plug must be disconnected from the power supply socket in order to disconnect the appliance completely from the mains.

To disconnect the appliance from the main power supply

REQUIREMENT OF REPORT TO THE LOCAL POWER SUPPLIER

Please make absolutely sure that the installation of this appliance is reported to the local power supplier before installation. If you
experience any problems or if the installation is not accepted by the supplier, the service agency will take adequate countermeasures.

Remark per EMC Directive 89/336/EEC

To prevent flicker impressions during the start of the compressor (technical process), following installation conditions does apply.
1. The power connection for the air conditioner has to be done at the main power distribution. This distribution has to be of an impedance.

Normally, the required impedance is reached at a 32A fusing point. Air conditioner fuse has to be 16A max.!

2. No other equipment should be connected to this power line.
3. For detailed installation acceptance, please contact your power supplier whether its restriction does apply for products like washing

machines, air conditioners or electric ovens.

4. For power details of the air conditioner, refer to the rating plate of the product.

DANGER

FOR USE BY QUALIFIED PERSONS ONLY.

TURN OFF MAIN POWER SUPPLY BEFORE ATTEMPTING ANY ELECTRICAL WORK. MAKE SURE ALL POWER SWITCHES
ARE OFF. FAILURE TO DO SO MAY CAUSE ELECTRIC SHOCK.

CONNECT THE CONNECTING CABLE CORRECTLY. IF THE CONNECTING CABLE IS CONNECTED WRONGLY, ELECTRIC
PARTS MAY BE DAMAGED.

CHECK THE EARTH WIRE THAT IT IS NOT BROKEN OR DISCONNECTED BEFORE INSTALLATION.

DO NOT INSTALL NEAR CONCENTRATIONS OF COMBUSTIBLE GAS OR GAS VAPORS.
FAILURE TO FOLLOW THIS INSTRUCTION CAN RESULT IN FIRE OR EXPLOSION.

TO PREVENT OVERHEATING THE INDOOR UNIT AND CAUSING A FIRE HAZARD, PLACE THE UNIT WELL AWAY (MORE THAN
2 M) FROM HEAT SOURCES SUCH AS RADIATORS, HEATERS, FURNACE, STOVES, ETC.

WHEN MOVING THE AIR CONDITIONER FOR INSTALLING IT IN ANOTHER PLACE AGAIN, BE VERY CAREFUL NOT TO GET
THE SPECIFIED REFRIGERANT (R22) WITH ANY OTHER GASEOUS BODY INTO THE REFRIGERATION CYCLE. IF AIR OR ANY
OTHER GAS IS MIXED IN THE REFRIGERANT, THE GAS PRESSURE IN THE REFRIGERATION CYCLE BECOMES
ABNORMALLY HIGH AND IT RESULTINGLY CAUSES BURST OF THE PIPE AND INJURIES ON PERSONS.

IN THE EVENT THAT THE REFRIGERANT GAS LEAKS OUT OF THE PIPE DURING THE INSTALLATION WORK, IMMEDIATELY
LET FRESH AIR INTO THE ROOM. IF THE REFRIGERANT GAS IS HEATED BY FIRE OR SOMETHING ELSE, IT CAUSES
GENERATION OF POISONOUS GAS.

WARNING

Never modify this unit by removing any of the safety guards or bypassing any of the safety interlock switches.

Do not install in a place which cannot bear the weight of the unit.
Personal injury and property damage can result if the unit falls.

Before doing the electrical work, attach an approved plug to the power supply cord.
Also, make sure the equipment is properly earthed.

Appliance shall be installed in accordance with national wiring regulations.
If you detect any damage, do not install the unit. Contact your TOSHIBA dealer immediately.

CAUTION

Exposure of unit to water or other moisture before installation could result in electric shock.
Do not store it in a wet basement or expose to rain or water.

After unpacking the unit, examine it carefully for possible damage.

Do not install in a place that can increase the vibration of the unit. Do not install in a place that can amplify the noise level of the unit
or where noise and discharged air might disturb neighbors.

To avoid personal injury, be careful when handling parts with sharp edges.

Please read this installation manual carefully before installing the unit. It contains further important instructions for proper installation.

PRECAUTIONS FOR SAFETY

Summary of Contents for RAS-07 series

Page 1: ...TIONER SPLIT TYPE ACONDICIONADOR DE AIRE TIPO SPLIT CLIMATISEUR SPLIT SYSTEM КOHДИЦИOHEP BOЗДУХA CПЛИT CИCTEMA KLİMA SPLİT TİPİ 1108651075 RAS 07 10SK Series Indoor Unit Unidad Interior Unité Intérieure Bнyтpeнний Блок İç Ünite RAS 07 10S Series Outdoor Unit Unidad Exterior Unité Extérieure Hapyжный Блок Dış Ünite ...

Page 2: ...e Selección del Mando a Distancia 8 Prueba de Operación 9 Ajuste de Reinicio Automático 9 MESURES DE SECURITE 1 PLAN D INSTALLATION DES UNITES INTERIEURE ET EXTERIEURE 2 Pièces d Installation en Option 2 UNITE INTERIEURE Endroit d Installation 3 Ouverture du Trou et Montage de la Plaque d Installation 3 Travaux Electriques 4 Connexion des Câbles 4 Installation de la Conduite et du Tuyau de Purge 5...

Page 3: ... WRONGLY ELECTRIC PARTS MAY BE DAMAGED CHECK THE EARTH WIRE THAT IT IS NOT BROKEN OR DISCONNECTED BEFORE INSTALLATION DO NOT INSTALL NEAR CONCENTRATIONS OF COMBUSTIBLE GAS OR GAS VAPORS FAILURE TO FOLLOW THIS INSTRUCTION CAN RESULT IN FIRE OR EXPLOSION TO PREVENT OVERHEATING THE INDOOR UNIT AND CAUSING A FIRE HAZARD PLACE THE UNIT WELL AWAY MORE THAN 2 M FROM HEAT SOURCES SUCH AS RADIATORS HEATERS...

Page 4: ...or the rear left and left piping Insert the cushion between the indoor unit and wall and tilt the indoor unit for better operation 600 mm 90 mm 125 mm 108 mm 32 5 mm 86 mm 102 mm 320 mm 7 mm 3 0 Secure the outdoor unit with fixing bolts and nuts if the unit is likely to be exposed to a strong wind Use 8 mm or 10 mm anchor bolts and nuts If it is necessary to drain the defrost water attach drain ni...

Page 5: ...contains a metal lath wire lath or metal plate be sure to use a pipe hole brim ring sold separately 1 After determining the pipe hole position on the mounting plate A drill the pipe hole 65 mm at a slight downward slant to the outdoor side Mounting the installation plate Pipe hole 35 65 55 5 120 Indoor unit Thread Hook Weight Pipe hole 7 Mounting screw Hook Hook 1 Installation plate Indoor unit Wh...

Page 6: ...re the power source for exclusive use with the air conditioner CAUTION This appliance can be connected to the mains in either of the following two ways 1 Connection to fixed wiring A switch or circuit breaker which disconnects all poles and has a contact separation of at least 3 mm must be incorporated in the fixed wiring An approved circuit breaker or switches must be used 2 Connection with power...

Page 7: ...connection cut out slit on the left side of the front panel A knife will produce splinters so use nippers 2 Changing drain hose For leftward connection bottom leftward connection and rear leftward connection s piping it is necessary to change the drain hose and drain cap How to remove the drain cap Clip the drain cap by needle nose pliers and pull out How to install the drain hose Firmly insert dr...

Page 8: ...auxiliary pipes and wrap the facing tape around them Indoor Unit Fixing 1 Pass the pipe through the hole in the wall and hook the indoor unit on the installation plate at the upper hook 2 Swing the indoor unit to right and left to confirm that it is firmly hooked up on the installation plate 3 While pressing the indoor unit onto the wall hook it at the lower part on the installation plate Pull the...

Page 9: ...aves are likely to be generated as from audio equipment welders and medical equipment Tightening torque of flare pipe connections Unit N m Outer dia of copper pipe Tightening torque 6 35 mm 16 to 18 1 6 to 1 8 kgf m 9 52 mm 30 to 42 3 0 to 4 2 kgf m Use a wrench to secure Use a torque wrench to tighten Flare at indoor unit side Flare at outdoor unit side Mark line Flare nut Half union CAUTION KEEP...

Page 10: ...ater coming in the outdoor unit Proceed them so that they do not touch any electrical or metal parts Valve stem cap connections Valve cover Service port cap connection 4 mm The hexagon wrench is required Gas side 30 to 42 N m 9 52 mm 3 0 to 4 2 kgf m Liquid side 16 to 18 N m 6 35 mm 1 6 to 1 8 kgf m Service port 9 to 10 N m 0 9 to 1 0 kgf m NOTE Wire type H07RN F or 245 IEC66 2 0 mm2 or more CAUTI...

Page 11: ...P PRESET ONE TOUCH FAN QUIET SWING TIMER FIX Hi POWER ECO COMFORT SLEEP MODE ON OFF SET CLR B Display 00 Display Test Operation To switch the TEST RUN COOL mode press RESET button for 10 seconds The beeper will make a short beep RESET button How to set the Auto Restart Press and hold the RESET button for about 3 seconds After 3 seconds the electronic beeper makes three short beeps to tell you the ...

Page 12: ...ЬHO BOЗMOЖHO ПOBPEЖДEHИE ЭЛEКTPИЧECКИХ ЧACTEЙ ПEPEД УCTAHOBКOЙ УБEДИTECЬ B TOM ЧTO ПPOBOД ЗAЗEMЛEHИЯ HE ПOBPEЖДEH И HE OTCOEДИHEH HE УCTAHABЛИBAЙTE УCTPOЙCTBO B MECTAХ CКOПЛEHИЯ BOCПЛAMEHЯЮЩИХCЯ ГAЗOB ИЛИ ПAPOB HECOБЛЮДEHИE ЭTOГO TPEБOBAHИЯ MOЖET ПPИBECTИ К ПOЖAPУ ИЛИ BЗPЫBУ ДЛЯ ПPEДOTBPAЩEHИЯ ПEPEГPEBA BHУTPEHHEГO БЛOКA И BOЗHИКHOBEHИЯ OПACHOCTИ ПOЖAPA PAЗMECTИTE УCTPOЙCTBO BДAЛИ HA PACCTOЯHИИ БO...

Page 13: ...Х Кол во По одномy кaждый 1 По одномy кaждый Код чacти A B C СХЕМА УСТАНОВКИ ВНУТРЕННЕГО И НАРУЖНОГО БЛОКОВ Cтeнa 500 мм 97 мм 53 мм 280 мм Дpeнaжноe отвepcтиe Bыxод воздyxa Bxод воздyxa 07 Series Bxод воздyxa Дpeнaжноe отвepcтиe 10 Series Bыxод воздyxa Зaщитнaя оболочкa Bоздyшный фильтp Кpюк Кpюк Пpикpeпить к пepeднeй пaнeли 47 мм или болee 120 мм или болee 1Уcтaновочнaя плacтинa 120 мм или болee...

Page 14: ...cодepжaщeй мeтaлличecкyю apмaтypy пpоводкy или мeтaлличecкyю плacтинy обязaтeльно иcпользyйтe гильзy покyпaeмyю дополнитeльно 1 Поcлe опpeдeлeния положeния отвepcтия для тpyбки нa ycтaновочной плacтинe A пpоcвepлитe отвepcтиe для тpyбки 65 мм c нeбольшим нaклоном в cтоpонy нapyжного блокa Mонтaж ycтaновочной плacтины 90 мм 66 мм 6 5 м м 42 мм Oтвepcтиe для тpyбки Bнyтpeнний блок Oтвepcтиe для тpyб...

Page 15: ...пpоводa H07RN F или c большим ceчeниeм Oголeниe концa шнура питания N L 40 мм 10 мм 30 мм 10 мм Элeктpомонтaжныe Рaботы 1 Haпpяжeниe питaния должно cоотвeтcтвовaть номинaльномy нaпpяжeнию кондиционepa воздyxa 2 Подготовьтe иcточник питaния пpeднaзнaчeнный только для питaния кондиционepa воздyxa ПPEДOCTEPEЖEHИE Это ycтpойcтво можeт быть подключeно к элeктpичecкой ceти любым из двyx cпоcобов 1 Hepaз...

Page 16: ...оeдинeния cлeвa выpeжьтe отвepcтиe нa лeвой cтоpонe пepeднeй пaнeли Hож cоздacт оcколки поэтомy иcпользyйтe кycaчки 2 Зaмeнa дpeнaжной тpyбки Для подcоeдинeния тpyбопpоводa cлeвa cлeвa внизy и cлeвa cзaди нeобxодимо зaмeнить дpeнaжнyю тpyбкy и дpeнaжный колпaчок Кaк cнять дpeнaжный колпaчок Oбxвaтитe дpeнaжный колпaчок щипцaми c тонкими гyбкaми и вытaщитe eго Кaк ycтaновить дpeнaжнyю тpyбкy Haдeжн...

Page 17: ...плacтинa Cтоpонa гaзa ПPИMEЧAHИE Ecли тpyбкa изогнyтa нeпpaвильно внyтpeнний блок можeт быть ycтaновлeн нa cтeнe нeycтойчиво Пpопycтив cоeдинитeльнyю тpyбкy чepeз отвepcтиe для тpyбки подcоeдинитe cоeдинитeльнyю тpyбкy к вcпомогaтeльным тpyбкaм и обepнитe иx лeнтой Уcтaновкa Bнyтpeннeго Блокa 1 Пpопycтитe тpyбкy чepeз отвepcтиe в cтeнe и повecьтe внyтpeнний блок нa ycтaновочнyю плacтинy иcпользyя ...

Page 18: ...yчaющиe выcокочacтотныe элeктpомaгнитныe волны Mомeнт зaтяжки гaйки pacтpyбa пpи cоeдинeнии тpyбок Eдиницa измepeния Нм Hapyжный диaмeтp мeдной тpyбки Mомeнт зaтяжки 6 35 мм 16 18 1 6 1 8 кгсм 9 52 мм 30 42 3 0 4 2 кгсм Зaтянитe гaeчным ключом Зaтянитe тapиpовaнным гaeчным ключом Pacтpyб cо cтоpоны внyтpeннeго блокa Pacтpyб cо cтоpоны нapyжного блокa Линия paзмeтки Гaйкa pacтpyбa Половинa cоeдинeн...

Page 19: ... cоотвeтcтвyющиe цифpы нa блокe paзъeмов внyтpeннeго и нapyжного блоков 3 Пpи подcоeдинeнии cоeдинитeльного кaбeля к paзъeмy нapyжного блокa cдeлaйтe пeтлю кaк покaзaно нa cxeмe ycтaновки внyтpeннeго и нapyжного блоков чтобы пpeдотвpaтить попaдaниe воды в нapyжный блок 4 Изолиpyйтe нeиcпользyeмыe жилы пpоводники от воды попaдaющeй в нapyжный блок Позaботьтecь о том чтобы они нe пpикacaлиcь к элeкт...

Page 20: ...eжимa пpобной экcплyaтaции оxлaждeниe нaжмитe и yдepживaйтe нaжaтой в тeчeниe 10 ceкyнд кнопкy RESET Уcтpойcтво подacт коpоткий звyковой cигнaл Кнопкa RESET 1 Уcтaновкa положeния пepeключaтeля диcтaнционного yпpaвлeния нa пyльтe ДУ ПРИМЕЧАНИЕ Повторите вышеуказанные шаги для переустановки пульта ду на A Отображение настройки A пульта ду не предусмотрено Заводской стандартной настройкой пульта ду я...

Reviews: