30
Q9 ASD Quick Start Guide
VI/II (V/I)
— Displays the
V/I
input setting as a percentage of the full range of the
V/I
value.
Note: The isolated VI/II (V/I) input terminal may receive Current or Voltage to control the
output speed or the output torque. The input signal type must be selected at SW301 on
the Terminal Board.
The V input setting of SW301 is used for the 0 – 10 VDC analog input signal and the
I input setting of SW301 is used for the 0 – 20 mA analog input signal. Either may be
used as a frequency or torque control source. Throughout this guide they will be
selection-specific and may be listed as VI/II (V/I).
See parameter F201 for more information on the setup of this input.
RX
— Displays the
RX
input setting as a percentage of the full range of the
RX
value (-10 to +10
VDC input).
RX2
— Displays the
RX2
input setting as a percentage of the full range of the
RX2
value.
Note:
The RX2 terminal function is available on the Expansion IO Card Option 1 option
board (P/N ETB003Z) only.
FM Output
—
Displays the magnitude of the function assigned to this terminal relative to the full-
scale reading of the
FM
terminal. This terminal may be configured at F005 for application-specific
suitability.
AM Output
—
Displays the magnitude of the function assigned to this terminal relative to the full-
scale reading of the
AM
terminal. This terminal may be configured at F670 for application-specific
suitability.
Fault
—
Displays the active fault or
No Error
if there are no errors.
Past Trip 1
—
This function records and displays the last trip incurred. Subsequent trips will replace
Past Trip 1
. As trip records are replaced they are shifted to the next level of the
Past Trip
locations
until being deleted (i.e.,
Past Trip 1
is moved to
Past Trip 2
and then to
Past Trip 3
until being
shifted out of
Past Trip 4
). Once shifted out of
Past Trip 4
the record is deleted. If no trips have
occurred since the last reset,
No Error
is displayed for each trip record.
Past Trip 2
—
Past trip information or
None
.
Past Trip 3
—
Past trip information or
None
.
Past Trip 4
—
Past trip information or
None
.
Note:
An improper ASD setup may cause some trips — reset the ASD to the Factory
Default settings before pursuing a systemic malfunction (Program
Utility Group
Type Reset
Factory Settings).
Direction
— Displays the
Direction
command (forward/reverse).
Discrete Input Terminals
— Displays the status (activated = reverse video) of the discrete input
terminals of the
Terminal Board
.
Discrete Output Terminals
— Displays the status (activated = reverse video) of the discrete
output lines of the
Terminal Board
.