158
Step Component
Procedure
Remarks
⑥
Interface
P.C. board
WARNING
Do not detach the inverter for 5 minutes after
turning off the breaker as doing so may cause
electric shocks.
1) Perform Step 1 of
①
and 3) of
⑤
.
2)
the board to remove the interface P.C.board.
3) Mount a new interface P.C. board.
Support (8 positions)
Interface P.C. board
⑦
P.C. board
WARNING
Do not detach the inverter for 5 minutes after
turning off the breaker as doing so may cause
electric shocks.
1) Perform Step 1 of
①
, Step 3) and Step 4) of
⑤
.
2)
P.C. board attachment plate, and pull the
attachment board in the direction of the arrow
to remove it.
(M4×8, 4)
3) Remove the connector connected between the
CN01 .....Connection with power supply terminal block (L) (black)
CN02 .....Connection with power supply terminal block (N) (white)
CN08 .....Connection with comp-IPDU P.C. board (CN511) (red)
P01 ........earth screw
4) Remove the 2 screws and support hooks (2
remove it.
5)
Screws
(4 positions)
Interface
P.C. board
attachment plate
Noise filter P.C. board
Support (2 positions)
Screws (2 positions)
A10-1510.indb 158
A10-1510.indb 158
2016/04/08 17:21:25
2016/04/08 17:21:25