background image

Safety Precautions 

Safety Precautions 

 

 

OIS-DS52 and the instruction manual give important information for using products 

safely. It helps prevent damage to properties and hazard to people who use them or to 
others. 

 

Make yourself familiar with the signal words and signs in this page then read the 

safety precautions that follow and always follow the instructions to avoid hazards. 

 

Explanation of signal words 

 

Signal word is a word that designates a degree or level of hazard seriousness.  

 

The words WARNING and CAUTION are used for the products. 

 

WARNING

 

Indicates a potentially hazardous situation which could result in death or 
serious injury, if you do not follow the instructions. 

CAUTION

 

Indicates a potentially hazardous situation which may result in minor or 
moderate injury and/or property damage, if you do not follow the instructions. 

 

Hazard alert shapes and symbols 

 

Following shapes and symbols are used in the safety precaution labels affixed to the 

products and in other places including operation manuals for giving safety instructions.  
 

 

Filled circle means "Mandatory Action" or "Do as indicated." 
Required action is shown in the circle or described near the circle. 

 

Circle band with a diagonal slash means "Prohibition" or " You must not do." 
Prohibited action is shown in the circle or described near the circle. 

 

Triangle means "Hazard Alerting" or "Be alert against hazard." 
The kind of hazard is shown in the triangle or described near the triangle. 

 

Exclamation point with a triangle is a safety alert symbol which indicates a potential hazard. 
It is used with a Signal Word. 

 

Square or rectangle means "Information Messages" or "Notice." 

 

 Make sure to observe the following points. 

WARNING 

System fault or data loss may occur, if the power fails or the power system (including 
the power switch) is turned off. Toshiba cannot assure any compensation for the 
resulting damages. Take precautions in advance to protect the system in order to 
prevent such event to take place. Also back up your data regularly to minimize the 
possible damage by loss of data as a result of such event. 

 

Summary of Contents for JOKC1

Page 1: ...Operator interface station Keyboard controller JOKC1 Operator s keyboard UOPK8UE 6F8C0808 Toshiba Integrated Control System ...

Page 2: ...ition January 2005 The contents of this manual may be revised without notice Copyright 2000 2005 by Toshiba Corporation All rights reserved No part of this manual may be reproduced in any form without permission ...

Page 3: ...tion labels affixed to the products and in other places including operation manuals for giving safety instructions Filled circle means Mandatory Action or Do as indicated Required action is shown in the circle or described near the circle Circle band with a diagonal slash means Prohibition or You must not do Prohibited action is shown in the circle or described near the circle Triangle means Hazar...

Page 4: ...hin the specified range for installation Location where the humidity exceeds the specified limits for installation Location in the direct sunlight Location near a device that generates strong radio waves or magnetic fields Considerations for maintenance and inspection Install the equipment in a place that facilitates maintenance and inspection If not in case of malfunctioning it may hinder the rec...

Page 5: ...d Static electricity may cause equipment to malfunction or fail Use a conductive mat or bag to avoid static When the JOKC1 card is removed from the OIS PC it should be placed on a conductive bag containing reserve cards etc or on a static proof mat which is put on a grounded work bench Static electricity may damage electrical parts Wipe off dirt Wipe off dirt and dust from the JOKC1 card and the k...

Page 6: ...ved static electricity may cause equipment failure or data damage Do not touch components Do not touch the JOKC1 card parts pins connectors or soldered surfaces with any part of your body Static electricity may damage IC s or LSI s and cause equipment to fail This may also result in damaging the pointed end of the component lead Do not disassemble the equipment Do not disassemble or modify the JOK...

Page 7: ... main control system for a nuclear power plant a safety protection system for nuclear power facilities and other important system for safety purpose Operation control system for mass transportation and air traffic control system Note 3 Special consideration means to construct safe system fool proof design fail safe design a tedious design upon much discussion with our engineer Exemption Matters fr...

Page 8: ...Safety Precautions vi ...

Page 9: ...ribes the procedure for incorporating Toshiba s software keyboard controller JOKC1 and operator s keyboard UOPK8UE into your personal computer to construct the operator interface station OIS DS for Toshiba s integrated control system TOSDIC CIE DS ...

Page 10: ...Introduction viii ...

Page 11: ...x x x x x x x x x x x x x x x x x x x x 4 3 Mounting the Card and Connecting the Keyboard x x x x x x x x 9 Mounting the Operator s Keyboard Control Card JOKC1 x x x x x x x x x x x 9 Connecting the Operator s Keyboard UOPK8UE x x x x x x x x x x x x x x x x x 11 4 Maintenance and Inspection x x x x x x x x x x x x x x x x x x x x x x x 13 Lifetime x x x x x x x x x x x x x x x x x x x x x x x x x...

Page 12: ...Contents x ...

Page 13: ...one of them is missing An operator s keyboard control card JOKC1 An attached RS 232C cable ZCDEYAA An instruction manual 6F8C0808 Note The operator s keyboard UOPK8UE and the keyboard cable ZCDEWAA are packed separately In case of ordering the control card as JOKC1 the control card will be shipped without the interfase cable and the manual Figure 1 1 Unpacking ...

Page 14: ...1 Unpacking 2 ...

Page 15: ...n Display LED 4 Communication Operation Display LED 2 Main Unit Connector CN2 Rotary SW Set always 2 Figure 2 1 Operator s Keyboard Control Card 1 Operator s keyboard connector CN1 Refers to the connector for connecting the operator s keyboard UOPK8UE Connected with a specialized twisted pair cable 2 Main unit connector CN2 Refers to the connector for connecting the COM1 port of the OIS DS main un...

Page 16: ...the remote keyboard section 7 8 9 4 5 6 1 2 3 0 SPACE UNLOCK ENTER Data Input Keys Execution Key User s Keys Alarm Keys UNLOCK Key Screen Manipulation Keys Hardcopy Key Screen Switching Keys NEW NEW WINDOW AW ARRANGE WINDOW NEXT NETX WINDOW BR BUZZER RESET CNF ALARM CONFIRM LO ALARM LIGHT OFF EXE EXECUTE PS PRENVIOUS SCREEN GB GO BACK 1 LEVEL BW BACK WARD FW FOR WARD HC HARD COPY BS BACK SPACE Fig...

Page 17: ... window GB GO BACK 1 LEVEL Higher Level Screen Key Can display the higher level screen of a currently undisplayed screen on the operator window BW BACK WARD Previous Page Key Can display the screen of the previous page of the currently displayed screen on the operator window FW FOR WARD Next Page Key Can display the screen of the next page of the currently displayed screen on the operator window D...

Page 18: ...ata that has been entered into the key input area EXE EXECUTE Execute Operation Key This key executes DO s ON OFF operation UNLOCK Unlock Key This key is for preventing careless operations HC HARD COPY Hard Copy HC Key This key is executed to get a hardcopy of the screen ...

Page 19: ... keys control the increase and decrease of the SV value The change volume is 1 of a second FAST Key Sets the change volume of the SV and MV values to 10 of a second While pressing this key press the SV operation key or the MV operation key SLOW Key Sets the change volume of the SV and MV values to 0 1 of a second While pressing this key press the SV operation key or the MV operation key MV Operati...

Page 20: ...2 Part Names and Operations 8 ...

Page 21: ...ruction manual before starting the installation After installing the JOKC1 card make sure to reconstruct the system by using the Setup program The current capacity of the JOKC1 card is up to 5V2A The current capacity is limited for the PC expansion slot Before installing the JOKC1 card make sure to check the current capacity of the PC s expansion slot The operator s keyboard control card JOKC1 is ...

Page 22: ... suitable PCI bus expansion slot as shown in Figure 3 2 and then fix the panel of the JOKC1 card with the single screw removed in 3 Figure 3 2 Fixing the Panel of the JOKC1 Card 5 Install the cover of the main unit 6 Install the front panel Thus installing the JOKC1 card is complete ...

Page 23: ...e operator s keyboard UOPK8UE and the connector CN1 of the operator s keyboard control card JOKC1 with the specialized cable Figure 3 3 shows how to connect these cables OIS DS Main Unit Keyboard Cable Type ZCDEWAA Ordering code 5X8C0003J01800 Cable length 1 8 m To connector CN1 To port COM1 To connector CN2 RS 232C Cable Type ZCDEYAA Ordering code 5X8C0003G00300 Cable length 30 cm Operator s Keyb...

Page 24: ...3 Mounting the Card and Connecting the Keyboard 12 ...

Page 25: ... 4 1 shows the lifetime of the operator s keyboard UOPK8UE For replacement choose a proper time such as the routine inspection Toshiba will not be responsible for any damages resulting when the lifetime of these units comes to an end while being used Table 4 1 Lifetime Type Unit Name Life Part Lifetime Toshiba recommended time UOPK8UE Operator s keyboard Switch contact Surface sheet 3 million time...

Page 26: ...4 Maintenance and Inspection 14 ...