Domestic Hot Water Heat Pump Service Manual
69
13.13 Replace the compressor
Tools:
BT20 Torx Screwdriver
, 8mm socket, reclaim equipment, brazing equipment
1.
Complete steps
13.1, 13.2 & 13.3
The compressor
is located at the rear
of the DHW-HP
The service port
is located to the right
of the refrigeration
circuit. Remove the
cap and connect the
reclaim equipment.
Using the 8mm
socket remove the
compressor
connection cap.
Take note of the
compressor
connections. Snip
the cable ties which
hold the lead in
place. Disconnect
the compressor
connections and
move the cable and
overload protector
away from
compressor location.
Remove the
insulation tape to the
compressor
discharge pipe and
peel back away from
the compressor
Using the brazing
equipment, de-braze
the suction and
discharge pipes
from the compressor
Remove the
compressor
retaining clips, 2 at
the front and 1 at the
rear, and lift the
compressor free
from the unit.