– 13 –
Air to Water Heat Pump
Installation Manual
• When collectively draining discharged water
completely, use a drain pan.
For Reference
If a heating operation is to be continuously performed
for a long time under the condition that the outdoor
temperature is 0 °C or lower, draining defrosted water
may be difficult due to the bottom plate freezing,
resulting in trouble with the cabinet or fan.
It is recommended to procure an anti-freeze heater
locally in order to safely install the air to water heat
pump.
For details, contact the dealer.
5
REFRIGERANT
PIPING
Knockout of Pipe Cover
Knockout procedure
• The indoor/outdoor connecting pipes can be
connected in 4 directions.
Take off the knockout part of the pipe cover through
which pipes or wires will pass through the base plate.
• Detach the pipe cover and tap on the knockout
section a few times with the shank of a screwdriver.
A knockout hole can easily be punched.
• After punching out the knockout hole, remove burrs
from the hole and then install the supplied protective
bush and guard material around the passage hole to
protect wires and pipes.
Be sure to attach the pipe covers after pipes have
been connected. Cut the slits under the pipe covers
to facilitate the installation.
After connecting the pipes, be sure to mount the pipe
cover. The pipe cover is easily mounted by cutting off
the slit at the lower part of the pipe cover.
* Be sure to wear heavy work gloves while working.
Drain nipple
Waterproof rubber cap
Waterproof rubber cap
Drain nipple
Knockout hole
Rear direction
Pipe cover
Side direction
Down direction
Front direction
13-EN
Summary of Contents for HWS-1103H-E
Page 29: ... 28 EN Air to Water Heat Pump Installation Manual MEMO 28 EN ...
Page 57: ... 56 Pompe à chaleur air eau Manuel d installation FR NOTES 28 FR ...
Page 85: ... 84 DE Luft Wasser wärmepumpe Installations handbuch NOTIZEN 28 DE ...
Page 113: ... 112 SE Luft till vatten värmepump Installationshandbok MEMO 28 SE ...
Page 114: ...EF99804801 ...