GD-1060 DIALING AND COMMUNICATION PROCEDURE
4 - 14
January 2001 © TOSHIBA TEC
Notes: 1. In the V.34 procedure, ECM is used. If the ECM transmission/reception of user data is set to
“Not performed”, the V.8 procedure is not performed. Therefore, the procedure does not switch
to V.34, and V.17 or the prior, is selected.
2. Also when the transmission/reception speed is set to 14.4 kbps or less, the V.8 procedure is not
performed, and V.17 or the prior, is selected.
3. To switch to the V. 8/V.34 procedure after starting V.21 procedure, see “c-1”.
4. After the V.34 procedure starts, fallback is performed in the V.34 procedure. However, fallback
for V.17 mode or before is not performed.