Test Equipment Required and Connections
• Oscilloscope, 100MHz
• Dummy Load, 50-ohm
• Frequency Counter
• DC Power Supply, 2.4V
Dummy Load
(50-ohm)
Digital Voltmeter
Oscilloscope
Frequency Counter
PORTABLE
RF Test
Point
Batt Terminal
DC Power Supply
2.4V
Alignment Point Location on Main PCB
Preset
Turn Power On (Connect battery) while depressing "
æ
" and " # " keys. A beep will be heard. Press the " 1 " key,
then the TX Mode is entered (CH1).
Alignment Procedure
L506
TX VCO Test Point
RF Test Point
Step
Adjustment
Remarks
1
L506
Set the digital voltmeter at the test point of TX VCO, then adjust L506 to indicate DC
0.8V ±0.05V.
2
!
Connect the frequency counter across a 50-ohm dummy load to RF test point. (See
page 25) Make sure that the frequency is 48.760 MHz ±1500Hz.