42
BASE UNIT
RECEIVER
UNIT
MIN
MAX
NOMINAL
1.Sensitivity at 12 dB SINAD
V
-
1.5
0.4
2.Selectivity (NQ 20 dB)
6dB Bandwidth
kHz
12
-
17
3.Signal to Noise Ratio
1mV RF Input
dB
60
-
66
4.Audio Output Level at Mod.1KHz ± 3KHzDeV
Tel Line output
dBm
-9.0
-3.0
-6.0
5.T.H.D.
%
-
7
2
6.Audio Freq. Response
300 Hz
dB
-4.5
+3.5
-0.5
3000 Hz
dB
-10
-2
-6
TRANSMITTER
UNIT
MIN
MAX
NOMINAL
1.RF Power at 50
Ω
Load
dBm
-11
-1
-6
2.TX Freq. Error
Hz
-1500
+1500
±400
3.Modulation Sensitivity Tel Line Input -18.0 dBm
KHzDEV
±2.0
±4.2
±3.0
4.Audio Freq. Response
Input Ratio REF. Freq. :1KHz
REF. DEV. : ± 3KHz
300 Hz
dB
-4.0
+4.0
0.0
3000 Hz
dB
-5.0
+3.0
-1.0
TELEPHONE LINE
UNIT
MIN
MAX
NOMINAL
1.Off-Hook Impedance ( at 1000Hz )
Ω
500
1500
1000
2.Off-Hook DC Resistance ( DC 40mA )
Ω
100
300
245
3.Min. Ringer Input Level (at 20Hz)
Vrms
-
40
23
4.Pulse Dialing
a. Dialing Rate
pps
8
11
10
b. Make Ratio
%
36
42
40
5.DTMF Dialing
a.Frequency
Row 1
Hz
687
707
697
Row 2
Hz
759
781
770
Row 3
Hz
840
864
852
Row 4
Hz
927
955
941
Column 1
Hz
1191
1227
1209
Column 2
Hz
1316
1356
1336
Column 3
Hz
1455
1499
1477
b.Signal Level of Single Tone
Low Group
dBm
-10
-
-7
High Group
dBm
-8
-
-5
c.Signal Level of Dual Tone
(Maximum Level on Frequency Pair)
dBm
-
0
-3
d.High Group/Low Group Component
dB
0
4
2
Summary of Contents for FT-7007LBR
Page 1: ... PUBLISHED IN JAPAN Nov 1998 0 10 2 3 456789 FT 7007LR FT 7007LBR ...
Page 8: ...7 BLOCK DIAGRAMS Base Unit ...
Page 9: ...8 Handset ...
Page 11: ...11 12 Handset RX VCO TEST POINT RF TEST POINT TX VCO TEST POINT DISCRI TEST POINT ...
Page 26: ...27 WIRING DIAGRAM Handset ...
Page 43: ......