4
Receiver
Test Equipment Required and Connections
• SG: RF Signal Generator, 49.830MHz
• Dummy Load, 600-ohm
• Digital Voltmeter
• AF SSVM
• SINAD Meter
AC Adapter
(120V 60Hz)
Digital Voltmeter
BASE Unit
RF Test
Point
TEL Jack
SG
MOD=1kHz
DEV=±3kHz
AF SSVM
SINAD
Meter
Dummy Load
(600-ohm)
Alignment Point Location on Main PCB
Preset
a) Set T/P SW to Pulse Mode.
b) Turn on AC power while the Page key is being depressed.
c) Release the Page key 2 second later, then the TX Mode is entered (CH21).
d) Press the Page key 4 times, then the DUPLEX Mode is entered (CH21).
Alignment Procedure
T/P SW
L4
S1
P
T
DISCRI Test Point
RX VCO Test Point
L2
RT2
RT1
RF Test Point
Step
Preset to
Adjustment
Remarks
1
SG: 1mV
No modulation
L4
Connect the SG to the RF test point.
Connect the digital voltmeter to the test point of the RX VCO.
Adjust L4 to indicate DC 3.3V ±0.05V.
2
SG: 1mV
No modulation
L2
Set the digital voltmeter at the test point of DISCRI.
Adjust L2 to indicate 2.0V ±0.05V.
3
SG: 1mV
1kHz ±3kHz
deviation
RT2
Connect the AF SSVM to the TEL LINE through a 600-ohm dummy
load, then adjust RT2 to indicate AC -6dBm ±0.5dBm.
4
SG: 0.2
"
V
No modulation
RT1
Press the Page key 2 times. Turn RT1 to fully clockwise and confirm
the STATUS LED turns off.
Then adjust RT1 to turn to counterclockwise slowly where the STATUS
LED just turns on.
Summary of Contents for FT-7007LBR
Page 1: ... PUBLISHED IN JAPAN Nov 1998 0 10 2 3 456789 FT 7007LR FT 7007LBR ...
Page 8: ...7 BLOCK DIAGRAMS Base Unit ...
Page 9: ...8 Handset ...
Page 11: ...11 12 Handset RX VCO TEST POINT RF TEST POINT TX VCO TEST POINT DISCRI TEST POINT ...
Page 26: ...27 WIRING DIAGRAM Handset ...
Page 43: ......