1. AUTOMATIC CALIBRATION (Cont.)
11
When the message “Scanning and
calibrating” goes out, all the operation is
completed.
12
Tip:
If you want to return the image quality
level to the default setting after the
calibration, press the DEFAULT key in
step 4.
Press the START key to start the second
calibration.
9
10
Press the CALIBRATION key, then set the
printed out chart on the glass in the same
way as the first calibration.
When the message “Scanning and
calibrating” disappears, press the TEST
PRINT key to print out the second test
chart.