400
Fuser
Fuser unit error status
counter
ALL
0
<0-51>
M
0: No error
7: C467
24: C446
31: C4D0
1
556
Image
control
Image quality closed-loop
control/Contrast voltage
ALL
1
<0-1>
M
Sets whether or not cor-
recting the contrast volt-
age in closed-loop
control.
0: Invalid
1: Valid
1
557
Image
control
Image quality closed-loop
control/Laser power
ALL
1
<0-1>
M
Sets whether or not cor-
recting the laser power
in closed-loop control.
0: Invalid
1: Valid
1
573
Image
control
Abnormality detection
count (Y)
Display/0 clearing
ALL
0
<0-16>
M
Counts the abnormality
detection of image qual-
ity control. Accumulat-
ing total of [CE10],
[CE20] and [CE40]
1
574
Image
control
Abnormality detection
count (M)
Display/0 clearing
ALL
0
<0-16>
M
Counts the abnormality
detection of image qual-
ity control. Accumulat-
ing total of [CE10],
[CE20] and [CE40]
1
575
Image
control
Abnormality detection
count (C)
Display/0 clearing
ALL
0
<0-16>
M
Counts the abnormality
detection of image qual-
ity control. Accumulat-
ing total of [CE10],
[CE20] and [CE40]
1
576
Image
control
Abnormality detection
count (K)
Display/0 clearing
ALL
0
<0-16>
M
Counts the abnormality
detection of image qual-
ity control. Accumulat-
ing total of [CE10],
[CE20] and [CE40]