(6) Rotate the carriage-1 in the direction shown
in the figure at right, not to touch the mirror.
Then take off the carriage-1.
Note:
When installing the carriage-1, fix the
bracket temporarily at the position (A). Then
move it to the direction (B) slowly, push it to
the end of frame and fix at this position with
the screws. (Refer to 3.7.1 in the Service
Handbook.)
(B)
(A)
(A)
Fig. 6-718
Fig. 6-719
Fig. 6-716
Fig. 6-717
Black line
Lamp harness
Lamp harness
Seal
Hole
Punched mark
Lamp harness
Seal
Punched mark
Note:
Make sure to hold only the black molded
part of the exposure lamp. Do not touch any
other part than this black molded part.
1. Using alcohol, clean the area where
the seal is to be attached..
2. Align the black line on the lamp harness
with the position as shown in the figure,
and fix it with a seal.
3. Align the bent portion of the lamp
harness with the position as shown in the
figure, and fix it with a seal.
4. After the installation, move carriage-1
towards the left and confirm that there is
no abnormality in the lamp harness, such
as twisting.