9-1
9. Troubleshooting
No Power Detected
(stand by LED OFF)
F1SS01 is normal?
D1S05~07, ZD1S01~2
SHORT and OPEN
are normal?
Check feedback IC1S02
Change short circuited or
opened parts
Change fuse
Check 2'st Voltage
Replace Q1S01
NO
NO
Is there voltage at
Collector of
Q1S01
NO
YES
YES
YES
Operation of
Q1S01 is
normal?
NO
YES
Key Operation or
Remote Control Error
Is the measurement of
power with in normal value?
End repairs
Check power and front connector
Check the circuity around the clock
Check the circuity around
IC601 reset
Check the soldering around the
IC601
Change IC701
NO
NO
Key operatious such
as STOP,PLAY,OPEN
are normal?
Check the circuity around the swith.
check the condition of commmunication
with Main Micom
(IC601,4,6,14,15,16,RRQ,SRQ,SCLK,
DATA-IN,DATA-OUT)
NO
YES
YES
Check the circuity
around IC601 reset?
Check the soldering
around IC601 good?
NO
YES
XT601 14.318MHz
oscillation is normal?
NO
YES
YES
STOP,PLAY,OPEN
Key operatious are
normal?
YES
Summary of Contents for D-VR3SU
Page 3: ...CONTENTS ...
Page 4: ...MEMO ...
Page 10: ...Precautions 1 6 MEMO ...
Page 22: ...Reference Information 2 12 MEMO ...
Page 24: ...Product Specification 3 2 MEMO ...
Page 25: ...4 1 4 Operating Instructions ...
Page 88: ...5 22 Disassembly and Reassembly MEMO ...
Page 100: ...6 12 Alignment and Adjustments MEMO ...
Page 115: ...Circuit Operating Descriptions 7 15 Fig 7 12 IC601 Block Diagram ...
Page 148: ...Circuit Operating Descriptions 7 48 MEMO ...
Page 160: ...VCR Deck Operating Description 8 12 Fig 8 14 Mecha Timing Chart ...
Page 174: ...VCR Deck Operating Description 8 26 MEMO ...
Page 200: ...Exploded View and Parts List 10 8 MEMO ...
Page 216: ...11 16 Electrical Parts List MEMO ...
Page 217: ...1 1 SHIBAURA 1 CHOME MINATO KU TOKYO 105 8001 JAPAN ...