2460 ADJUSTMENT
1 - 34
September 1997 © TOSHIBA CORP.
0
5
3
0
5
d) Scanner secondary scanning deviation
(1) Make the adjustment values for the original leading edge void to “0”, and the cutting volume of
scanner leading image edge to “128”.
(2) Place the scale (its end to the left side original scale) on the original glass and make an
A3 400% copy.
(3) In order to correct the distance “F”, which should be 42
±
0.5 mm from the leading edge of the
paper, adjust as follows.
Notes 1. An increase in the value makes the image move to the trailing edge (0.1213 mm/
step).
2. In order to make a test copy, make sure the message indicates [100 %
A]
after the INT key is pressed.
3. Adjustment value is able to be input within the range of “85 ~ 171”.
The default adjustment value is 135.
Copy movement direction
Set the value
(Test copy)
START
INT
PWR
START
INT
PWR
Input the “0” with
the digital keys
0
5
3
1
5
3
1
3
START
INT
Input the “128”
with the digital keys
10
F
E/S