September 1997 © TOSHIBA CORP.
1 - 31
2460 ADJUSTMENT
1.5.3
Scanner unit adjustment
a) Polygonal motor 600 dpi/PPC
(1) Place the scale on the original glass (vertical to the direction of the copy paper movement)
and make an A4 100% copy.
(2) Measure and compare the copy and the scale.
(3) In order to correct the copied image to the scale, adjust as follows.
Notes 1. An increase in the value corresponds to an increase in the division of the scale
(0.225 % / step).
2. In order to make a test copy, make sure the message indicates [100 %
A]
after the INT key is pressed.
3. Adjustment value is effective within the range of 114 ~ 142.
The default adjustment value is 128.
Copy movement direction
START
Set the value
INT
(Test copy)
Copied Scale
Actual Scale
0
5
4
0
0
PWR
E/S