1 - 26
1550 ADJUSTMENT
Oct. 1995 © TOSHIBA CORP.
5
100% manual photo exposure adjustment
Sequence
Operation
Display after operation (typical)
5-1
5-2
5-3
5-4
5-5
Input code “14” using the digital keys, and press the “Print” key.
[When density is high]
Increase the numerical value, using the “Zoom” key.
[When density is low]
Decrease the numerical value, using the “Zoom” key.
Press the “Interrupt” key and store the numerical value in the
memory.
Press the “Energy saver” key and make a test copy.
If the image density of the test copy is not satisfactory, repeat
operations 5-1 through 5-4.
128
138
118
1442443
AJ
(4) Adjust exposure in accordance with the procedures shown in the charts below, if requested by the
user for separate adjustment of manual/auto-exposure.
Adjustment
Exposure mode
Reproduction
Adjustment code
sequence
ratio
1
100%
1
2
Manual exposure center
154%
2
3
50%
3
4
200%
4
5
100%
5
6
Automatic exposure
154%
6
7
50%
7
8
100%
8
9
Light (max.)
9
10
Dark (min.)
10
11
100%
14
12
Manual photo exposure
154%
15
13
50%
16
14
200%
17
100 % or
appropriate ratio