139 / 172
Copyright © 2019 Toshiba Teli Corpotration, All rights reserved.
http://www.toshiba-teli.co.jp/en/
D4289451A
UserSetControl
You are able to save a user setting to the non-volatile or volatile memory of the camera. There are 15 user
memory channels for user setting.
By using user memory, you are able to restore frequent used settings at the time of next start-up.
The following table is the list of registers applied to “UserSetLoad”/“UserSetSave”,“UserSetQuickSave”.
Table:
List of registers to be applied to UserSet
Category
Register
Category
Register
ImageFormatControl
ImageFormatSelector
DigitalIOControl
AntiGlitch
Width
AntiChattering
Height
TimerControl
TimerTriggerSource
OffsetX
TimerDuration
OffsetY
TimerDelay
Binning
AnalogControl
Gain
Decimation
GainControl
Reverse
BlackLevel
PixelFormat
Gamma
TestPattern
BalanceRatio
AcquisitionControl
AcquisitionFrameRateEnable
BalanceWhiteAuto
AcquisitionFrameRate
Sharpness
AcquisitionFrameIntervalControl
ALCControl
ALCExposureValue
AcquisitionFrameInterval
ALCPhotometricAreaSize
TriggerControl
TriggerMode
LUTControl
LUTEnable
TriggerSequence
EventControl
EventNotification
TriggerSource
DPCControl
DPCEnable(*)
TriggerAdditionalParameter
DPCNumber(*)
TriggerDelay
DPCEntryX(*)
ExposureControl
ExposureTime
DPCEntryY(*)
ExposureControl
SequentialShutterControl
SequentialShutterEnable(*)
DigitalIOControl
LineModeAll
SequentialShutterTerminateAt(*)
LineInverterAll
SequentialShutterEntry(*)
UserOutputValueAll
LineSelector
LineSource
(*) DPC and SequentialShutter entries are stored to a single channel. Entries are shared with all channels.
This table lists all features of B/W and Color models. Please refer to [Table : supported features list] as well.