Transducer Control 5 User Manual (RWT3746IM)
Revision 5, December 2016 - Page 17
To enable Limits click the “Enable Limits” checkbox.
Channel Select
The “Channel Select” option selects the control channel to be used with the limits
feature. The user can select between torque and speed.
Output Mode
The “Output Mode” option selects the polarity of the active / triggered state.
Active High
Active / triggered state is high, inactive is low.
Active Low
Active / triggered state is low, inactive is high.
Samples Required Before Trigger
The “Samples Required Before Trigger” parameter sets the number of continuous
samples that must exceed the high/low limits, before the limit output is set to the
active / triggered state.
Use the “Samples Required Before Trigger” slider bar to select a value, the slider
is scaled from 0 to 1000 in increments of 10.
Low / High Limits
The “Low” and “High” limits set the trigger thresholds that control the limit output.
Low, High or both limits must be selected to use the Limits feature. The High
value must not be lower than the Low value and vice versa.
Enable the High/Low limit by clicking the High/Low checkbox, then use the
High/Low slider bar to select the trigger level.