7. Check where the control lever is relative to
notch in console (Figure 67). It should be
centered allowing lever to pivot outward to the
neutral lock position.
Figure 67
1. Neutral locked position
3. Neutral position
2. Control lever
8. If adjustment is needed, loosen the nut and
jam nut against the yoke (Figure 68).
9. Apply slight rearward pressure on the motion
control lever, turn the head of the adjustment
bolt in the appropriate direction until the
control lever is centered in the neutral lock
position (Figure 68).
Note:
Keeping rearward pressure on the
lever will keep the pin at the end of the slot and
allow the adjustment bolt to move the lever to
the appropriate position.
10. Tighten the nut and jam nut (Figure 68).
11. Repeat for the opposite side of the machine.
Figure 68
1. Clevis pin in slot
7. Spring
2. Nut against yoke
8. Pivot shaft
3. Adjustment bolt
9. Yoke
4. Pump rod
10. Locknut
5. Double nuts
11. Ball joint
6. Jam Nut
12. Tracking knob
Hydraulic System
Maintenance
Servicing the Hydraulic
System
Checking the Hydraulic Fluid
Fluid Type: Mobil 1 15W-50 synthetic motor oil or
equivalent synthetic oil.
Important:
Use oil specified or equivalent.
Other fluids could cause system damage.
Hydraulic System Oil Capacity: 132 ounces (3.9 l)
Check the hydraulic fluid level:
•
Before the engine is first started.
•
After the first 8 operating hours.
•
After every 25 operating hours.
Note:
There are two ways of checking the
hydraulic oil. One is when the oil is warm and one
is when the oil is cold. The baffle inside the tank
has two levels depending if the oil is warm or cold.
1. Position the machine on a level surface and set
the parking brake.
50
Summary of Contents for Z597-D Z Master
Page 7: ...Slope Chart 7 ...
Page 10: ...106 7492 106 9989 107 1613 110 2067 10 ...
Page 11: ...110 2068 1 Read the Operator s Manual 107 1857 107 1860 107 1861 107 1864 11 ...
Page 13: ...107 7705 107 9863 107 9864 1 Read the Operator s Manual 13 ...
Page 14: ...107 9866 1 Fast 2 Slow 3 Neutral 4 Reverse 14 ...