ProForce Debris Blower
Page 4
−
11
Electrical System
Fuse
The ProForce Debris Blower uses a 15 amp fuse for cir-
cuit protection. The fuse holder for this fuse is located
next to the engine (Fig. 8).
Testing
1. Make sure that ignition switch is OFF.
2. To prevent unexpected machine operation, discon-
nect the negative battery cable from the battery termi-
nal. Position disconnected negative cable away from
the negative battery terminal.
3. Remove fuse from the fuse holder for testing. Fuse
should have continuity between fuse terminals.
4. After testing, install fuse into fuse holder.
5. Connect negative battery cable to negative battery
terminal. Tighten nut that secures battery cable from
10
to 15 ft
−
lb (14 to 20 N
−
m)
. Make sure that battery cover
is secured.
1. Wire
harness
2. Fuse
3. Fuse
cover
Figure 8