Page 6 − 31
Electrical System
Service and Repairs
NOTE: For additional electrical component service and
repair information, see the Kubota Workshop Manual for
05 Series Diesel Engines, or the Kubota Workshop and
Diagnostics Manuals for WG972 Gasoline Engines.
Battery Care
1. The top of the battery must be kept clean. lf the ma-
chine is stored in a location where temperatures are ex-
tremely high, the battery will discharge more rapidly
than if the machine is stored in a location where temper-
atures are cool.
WARNING
Wear safety goggles and rubber gloves when
working with electrolyte. Charge battery in a
well ventilated place so gasses produced while
charging can dissipate. Since the gases are ex-
plosive, keep open flames and electrical sparks
away from the battery; do not smoke. Nausea
may result if the gases are inhaled. Unplug char-
ger from electrical outlet before connecting or
disconnecting charger leads to or from battery
posts.
IMPORTANT: Do not remove fill caps (if equipped)
while cleaning the battery.
2. Check battery condition weekly or after every 50
hours of operation. Keep terminals and entire battery
case clean because a dirty battery will discharge slowly.
A. Clean battery by washing entire case with a solu-
tion of baking soda and water. Rinse with clear water.
B. Coat battery posts and cable connectors with bat-
tery terminal protector (Toro Part No. 107−0392) or
petroleum jelly to prevent corrosion.
3. Battery cables must be tight on terminals to provide
good electrical contact.
Connecting battery cables to the wrong battery
post could result in personal injury and/or dam-
age to the electrical system.
WARNING
4. If corrosion occurs at terminals, disconnect cables.
Always disconnect negative (−) cable first. Clean
clamps and terminals separately. Reconnect cables
with positive (+) cable first. Coat battery posts and cable
connectors with battery terminal protector (Toro Part No.
107−0392) or petroleum jelly to prevent corrosion.
5. If the battery electrolyte is accessible, check electro-
lyte level every 25 operating hours and every 30 days if
machine is in storage. Maintain cell level with distilled
water. Do not fill cells above the fill line.
Electrical
System
Summary of Contents for Groundsmaster 3500 30807
Page 1: ...Form No 14209SL Rev C Groundsmaster 3500 Models 30807 and 30809 Original Instructions EN ...
Page 4: ...NOTES _ ...
Page 6: ...Groundsmaster 3500 This page is intentionally blank ...
Page 8: ...Groundsmaster 3500 This page is intentionally blank ...
Page 14: ...Page 1 6 Safety Groundsmaster 3500 This page is intentionally blank ...
Page 22: ...Groundsmaster 3500 D Page 3 2 Kubota Diesel Engine This page is intentionally left blank ...
Page 38: ...Groundsmaster 3500 D Page 3 18 Kubota Diesel Engine This page is intentionally left blank ...
Page 40: ...Groundsmaster 3500 G Page 4 2 Kubota Gasoline Engine This page is intentionally left blank ...
Page 194: ...Groundsmaster 3500 Hydraulic System Page 5 136 This page is intentionally blank ...
Page 230: ...Groundsmaster 3500 Page 6 36 Electrical System This page is intentionally blank ...
Page 259: ...Groundsmaster 3500 Cutting Decks Page 8 7 This page is intentionally blank Cutting Decks ...
Page 268: ...Groundsmaster 3500 Cutting Decks Page 8 16 This page is intentionally blank ...
Page 272: ...Groundsmaster 3500 Cutting Decks Page 8 20 This page is intentionally blank ...
Page 279: ...Page 9 7 Harness Drawing Groundsmaster 3500 D SERIAL NUMBER ABOVE 314000001 ...
Page 283: ...Page 9 11 Harness Drawing Groundsmaster 3500 G ...